background image

addressing  of  the 

fixtures

 

Bad 

data 

link 

connection

 

Inspect  cables  and  correct  poor  connections 

and/or broken cables.

 

Conflict 

between 

tracking  and  vector 

control

 

Eliminate scene cross-fade on controller 

 

Data 

link 

not 

terminated

 

Insert termination plug in output of last fixture

 

controller(DMX 

mode operation)

 

Defective  fixture  or 

devices 

transmitting on link

 

Bypass  fixtures  one  at  a  time  until  normal 

operation is regained: unplug both connectors 

and connect them directly together

 

Colors  cannot  be 

mixed

 

Random 

color 

mixing is on

 

Turn off random color mixing 

 

Fixture  does  not 

reset correctly

 

Electronic 

or 

mechanical failure

 

Contact service technician

 

Lamp  missing  or 

blown

 

Disconnect fixture and replace lamp

 

No light, lamp cuts 

out intermittently, or 

burns out too 

quickly

 

Fixture  or  lamp  is 

too hot

 

Allow  fixture  to  cool.  If  problem  persists, 

contact service technician

 

 

 

 

 

 

 

 

 

 

 

 

Section 4. Reference

 

 

Control Menu 

 

 

DMX Protocol

 

 

Dimmer Curve

 

 

Specification

 

Summary of Contents for YR-COB5002

Page 1: ...100W COB LED Model YR COB5002...

Page 2: ...packing 1pc Fixture 1 4pc Signal Convertor Cable 1pc User Manual Thanks for choosing our product Carefully unpack the box and check the contents to ensure that all parts are present and in good condit...

Page 3: ...re to replace with same fuse lamp size and type Cut off power before moving repairing and cleaning the machine To avoid electric shock all fixtures must be connected to circuits with a suitable earth...

Page 4: ...nnection Installation This machine should be mounted through the screw holes of truss Safety rope is a must to fix fixture well Make sure truss and safety rope have strong load capacity to bear more t...

Page 5: ...on Menu Switch menu function UP Scroll upwards DOWN Scroll downwards ENTER Confirm by pressing ENTER 3 DMX Signal Input 3 PIN XRL port for DMX512 signal input daisy chain 4 DMX signal output 3 PIN XRL...

Page 6: ...ne machine as master press the menu to choose the function you want Press other machines address to be DMX state Use signal cable to connect machines one by one Then slave machines will run the same a...

Page 7: ...res one at a time until normal operation is regained unplug both connectors and connect them directly together Colors cannot be mixed Random color mixing is on Turn off random color mixing Fixture doe...

Page 8: ...dr 1 Dimmer Curve1 dr 2 Dimmer Curve2 dr 3 Dimmer Curve3 dr 4 Dimmer Curve4 DMX protocol DMX512 Channel Chart 5CH CH Function Specification CH1 All Dimmer 0 255 RGBW Dimmer from dark to bright CH2 PW...

Page 9: ...Curve 3 dr 3 1600 1710 Dimmer Curve 4 dr 4 1850 1980 Specification Voltage AC110V 240V Frequency 50 60Hz Machine Power 100W LED source 50W PW 50W WW LED QTY 1pcs Strobe 0 20 Hz Dimmer 4 kinds of dimme...

Page 10: ...Size 26 26 11 5cm excluding bracket Our company reserve right to revise this user manual without notice Innovation Efficiency Dedication Harmonious...

Page 11: ......

Reviews: