background image

Control Menu 

 

No.

 

Menu

 

Function

 

1

 

d3--

 

DMX 3 channel control(need connecting controller)

 

2

 

d

.

1-

 

DMX 1 channel control(need connecting controller)

 

3

 

n---

 

r000 to r255: White from dark to bright

 

4

 

F---

 

F000 to F255

flash speed

from slow to fast

 

5

 

T---

 

on: high temperature with half power function on

 

off:high temperature with half power function off

 

When the LED board temperature increase up to be 80

℃,

the  Max.  power  consumption  of  LED  source  would  be 

50%  ;  When  the  LED  source  temperature  decrease  to  

be  58

℃ ,

the  Max.  power  consumption  of  LED  source 

would be 100% ;

 

6

 

dr--

 

dr-0

Standard Dimmer Curve

 

dr-1

Dimmer Curve1

 

dr-2

Dimmer Curve2

 

dr-3

Dimmer Curve3

 

dr-3

Dimmer Curve4

 

 

DMX protocol

 

DMX512 Channel Chart

:(

3CH

 

 

CH

 

Function

 

Specification

 

CH1

 

Dimmer

 

0-255 White Dimmer, from dark to bright

 

CH2

 

Flash

 

1-255 flash speed

from slow to fast

 

CH3

 

Macro function

 

000-020

Standard Dimmer Curve

 

021-040

Dimmer Curve1

 

041-060

Dimmer Curve2

 

061-080

Dimmer Curve3

 

081-100

Dimmer Curve4

 

101-149

No Function

 

150-155

after  3  second,  high  temperature 

with half power function off

 

156-199

No Function

 

200-205

after 3 second, high temperature 

with half power   function on

 

206-255

No Function

 

 

 

DMX512 Channel Chart

:(

1CH

 

CH

 

Function

 

Specification

 

CH1

 

Dimmer

 

0-255 White Dimmer, from dark to bright

 

 

Summary of Contents for YR-COB100W

Page 1: ...100W White COB LED Model YR COB100W ...

Page 2: ...npacking 1pc Fixture 1 4pc Signal Convertor Cable 1pc User Manual Thanks for choosing our product Carefully unpack the box and check the contents to ensure that all parts are present and in good conditions If anything damaged in transit notify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to...

Page 3: ...re to replace with same fuse lamp size and type Cut off power before moving repairing and cleaning the machine To avoid electric shock all fixtures must be connected to circuits with a suitable earth connection Always secure fixture using a safety chain and carrying handles Do not operate at ambient temperatures higher than 104 40 The power cable for this fixture is 0 5 m please mind the safety re...

Page 4: ...onnection Installation This machine should be mounted through the screw holes of truss Safety rope is a must to fix fixture well Make sure truss and safety rope have strong load capacity to bear more than 3 times of machine weight This machine should be installed by qualified technician ...

Page 5: ...ton Menu Switch menu function UP Scroll upwards DOWN Scroll downwards ENTER Confirm by pressing ENTER 3 DMX Signal Input 3 PIN XRL port for DMX512 signal input daisy chain 4 DMX signal output 3 PIN XRL Port for DMX512 signal output daisy chain 5 Power Input AC power cable port input ...

Page 6: ...one machine as master press the menu to choose the function you want Press other machines address to be DMX state Use signal cable to connect machines one by one Then slave machines will run the same as master machine Use controller to control lot of machines if all machines are set the same menu data or different manual data after use signal cable to connect to controller all machines will be con...

Page 7: ...ures one at a time until normal operation is regained unplug both connectors and connect them directly together Colors cannot be mixed Random color mixing is on Turn off random color mixing Fixture does not reset correctly Electronic or mechanical failure Contact service technician Lamp missing or blown Disconnect fixture and replace lamp No light lamp cuts out intermittently or burns out too quic...

Page 8: ...ource would be 100 6 dr dr 0 Standard Dimmer Curve dr 1 Dimmer Curve1 dr 2 Dimmer Curve2 dr 3 Dimmer Curve3 dr 3 Dimmer Curve4 DMX protocol DMX512 Channel Chart 3CH CH Function Specification CH1 Dimmer 0 255 White Dimmer from dark to bright CH2 Flash 1 255 flash speed from slow to fast CH3 Macro function 000 020 Standard Dimmer Curve 021 040 Dimmer Curve1 041 060 Dimmer Curve2 061 080 Dimmer Curve...

Page 9: ... AC110V 240V Frequency 50 60Hz Machine Power 100W LED source 100W White LED Pure white 6000 6500K Warm white 3000 3200K Cold white 7500 8000K LED QTY 1pcs Strobe 0 20 Hz Dimmer 4 kinds of dimmer methods Fan 1pcs temperature detect fan Noise Same as Ambient noise away 1 5m Beam Angle 60 can be changed by barn door Control Mode DMX512 Manual Channel 3 1CH switchable Net weight 1 5kg Size 26 26 11 5c...

Page 10: ...本公司有权对此份产品说明书进行修改 恕不另行通知 Our company reserve right to revise this user manual without notice Innovation Efficiency Dedication Harmonious ...

Page 11: ......