yellow jacket EVac I Operation And Maintenance Manual Download Page 8

BACKLIGHT

To activate the Backlight temporarily, press 

 once.  The 

 indicator on the display will flash, 

and the backlight will turn off automatically after 1 minute.  To activate the Backlight permanently, 

press 

 again. The 

 indicator on the display will show solid.  Turn off the backlight by pressing 

 repeatedly until the 

 indicator turns off.  During Sleep Mode, the backlight will turn off to help 

conserve battery power, but will turn on again automatically upon resumption of normal operation if it

was previously set in the permanent-on mode. 

SOUND

The 

EVac I

 has an internal speaker that will emit a beep for each valid key press, and also functions 

as an alarm in the Calibration mode (see the Calibration section below).  It will also beep every 5 

minutes in Sleep Mode.  For silent operation, the sound can be muted by pressing and holding the 

key.  The Calibration mode alarm is not affected by the mute status.  The   indicator on the LCD 

display indicates that the sound is on (not muted).

SWIVEL HOOK

The 

EVac I

’s removable stainless steel swivel hook enables hanging of the gauge and will allow it to 

swivel freely in any direction.  The gauge may be operated with or without the hook attached. When 

fastening the hook to the gauge, turn it finger tight only. Use of a tool to tighten the hook may result in 

damage to the 

EVac I

 case. 

MAINTENANCE

The 

EVac I

should provide many years of service with no maintenance required. When not in use, the 

dust cap should remain in place over the sensor port.  Clean the plastic enclosure with a damp (not 

wet) rag.  Mild detergent is acceptable, but use no solvents.  Take care not to expose the vacuum 

sensor to oil.  If the Oil Sensor (described above) indicates a contaminated sensor, follow the Sensor

Cleaning Procedure below.  

CLEANING THE VACUUM SENSOR

If the vacuum sensor becomes contaminated with oil (as indicated by the Oil Sensor), carefully follow 

this procedure: 

1.  Turn the 

EVac I

 power off. 

2.  Shake the gauge to remove any large quantities of oil from the sensor. 
3.  Apply a few drops of rubbing alcohol inside the sensor vacuum port.  (

DO

OBJECT INTO THE PORT, AS THIS WILL PERMANENTLY DAMAGE THE SENSOR

4.  Place your finger over the port and shake for a few moments. 
5.  Remove your finger and shake out the alcohol. 
6.  Repeat steps (3) – (5) at least three times. 
7.  Allow the sensor to air dry over at least an hour, or pull a vacuum on the sensor to clean it more 

quickly.  

8.  Replace the battery and turn on the gauge.  The Oil Indicator should be off.  If it is still on, repeat 

the cleaning procedure. 

9.  If full accuracy is desired, perform a calibration cycle as detailed in the Calibration section below.

Note

: It is important to remove all alcohol vapors from the sensor, either through air

vacuum. Any remaining vapors will cause an incorrect vacuum reading. 

tor on the display will flash, 

and the backlight will turn off automatically after 1 minute.  To activate the Backlight permanently, 

indicator on the display will show solid.  Turn off the backlight by pressing 

indicator turns off.  During Sleep Mode, the backlight will turn off to help 

conserve battery power, but will turn on again automatically upon resumption of normal operation if it

nternal speaker that will emit a beep for each valid key press, and also functions 

as an alarm in the Calibration mode (see the Calibration section below).  It will also beep every 5 

ressing and holding the 

indicator on the LCD 

f the gauge and will allow it to 

swivel freely in any direction.  The gauge may be operated with or without the hook attached. When 

fastening the hook to the gauge, turn it finger tight only. Use of a tool to tighten the hook may result in 

should provide many years of service with no maintenance required. When not in use, the 

dust cap should remain in place over the sensor port.  Clean the plastic enclosure with a damp (not 

ptable, but use no solvents.  Take care not to expose the vacuum 

sensor to oil.  If the Oil Sensor (described above) indicates a contaminated sensor, follow the Sensor

aminated with oil (as indicated by the Oil Sensor), carefully follow 

NOT INSERT ANY 

OBJECT INTO THE PORT, AS THIS WILL PERMANENTLY DAMAGE THE SENSOR

). 

ir dry over at least an hour, or pull a vacuum on the sensor to clean it more 

Replace the battery and turn on the gauge.  The Oil Indicator should be off.  If it is still on, repeat 

alibration cycle as detailed in the Calibration section below.

: It is important to remove all alcohol vapors from the sensor, either through air-drying or via 

Summary of Contents for EVac I

Page 1: ...EVac I Digital Vacuum Gauge 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...ut the Size of a Manifold Gauge Long Battery Life Calibration Self Test Can be field calibrated with no special equipment Ideal for HVAC R Service and Industrial Use SPECIFICATIONS s n o r c i M 0 0 0...

Page 3: ...PARTS DIAGRAM...

Page 4: ...tes that Temperature is Displayed on the Alternate Numeric Display during calibration Indicates degrees Celsius on the Alternate Numeric Display during calibration Pascal Units Indicator Millibar Unit...

Page 5: ...MPORTANT TO PREVENT DAMAGE FROM LEAKING BATTERIES DO NOT LEAVE A DEAD BATTERY INSIDE THE EVac I REMOVE BATTERY IF THE EVac I IS NOT TO BE USED FOR AN AN EXTENDED PERIOD OF TIME BATTERY LEVEL INDICATOR...

Page 6: ...ll detect this condition condition If the OIL indicator in the display illuminates this is an indication that the vacuum sensor has been contaminated and is no longer functioning accurately If the sen...

Page 7: ...determination of the vacuum level achieved Each bar corresponds to a vacuum pressure range depending on units according to the following table Units Bar Value Microns Pa Millibar Millitorr mmHg 10K 10...

Page 8: ...ENSOR 4 Place your finger over the port and shake for a few moments 5 Remove your finger and shake out the alcohol 6 Repeat steps 3 5 at least three times 7 Allow the sensor to air dry over at least a...

Page 9: ...ed in an area with a room temperature of at least 23 no greater than 30 C 86 F 10 Allow the EVac I to warm to 20 C 68 F At this point the alarm will sound and show on the display 11 Press any key to s...

Page 10: ...ring Calibration Restart Calibration Leave the Gauge Undisturbed During Warming Phase LOW TEMPERATURE OPERATION The EVac I can operate accurately at temperatures as low as 10 F 12 C While operating be...

Page 11: ...NOTES...

Page 12: ...4 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Reviews: