yellow jacket 69336 Instruction And Operation Manual Download Page 7

 

PROBLEM

 

CHECK

 

REPAIR OR REPLACE

 

No power 

 

Check for weak or reversed     
batteries 

 

Replace batteries 

Stays in "warm up" 
mode 

 

Sensor not plugged into socket 
correctly 

 

Sensor open/defective 

 

Make sure sensor is pushed all the 
way down into socket 

 

Replace sensor 

No detection 

 

Check sensor with leak standard 
bottle 

 

Check if the filter is dirty or sensor 
opening is plugged 

 

Replace sensor 

 

 

Replace filter or clean out opening 

Slow recovery after 
detection 

 

Check if filter is dirty or sensor 
opening is plugged 

 

Replace filter or clean out opening  

No beeping 

 

Nothing 

 

Press mute button (if equipped) 

     to turn speaker back on 

Troubleshooting Guide 

Replacement Parts 

 

AccuProbe UV 

and  

AccuProbe II 

 

Parts kit (sensor, filters and leak standard bottle) 

69383 

Sensor and filter 

69384 

Sensor filters (package of 5) 

69385 

Leak standard bottle 

69386 

A/C Adapter   Input:  115V 60Hz                 

UL

 listed 

69380 

A/C Adapter

EU/UK Plug   Input: 230V 50Hz    

CE

 & 

T

Ü

Approved 

69381 

A/C Adapter

AU/NZ Plug   Input: 230V 50Hz    

CE

 & 

T

Ü

Approved 

69378 

Battery cover and screw 

69388 

Carrying case - blow molded with inserts 

69387 

AccuProbe  II

 

Carrying pouch 

69361 

 
 
 

 
AccuProbe UV 

 

Certified to the European Standard EN 14624 (Section 13) 

Minimum sensitivity R-134a fixed position 

1 gram/year 

Maximum sensitivity R-134a fixed position 

>50 gram/year 

Minimum sensitivity R-134a in motion 

3 gram/year 

Maximum sensitivity R-134a in motion 

>50 gram/year 

Minimum time for detection 1 gram/yr R-134a 

1 second 

Zeroing time for 50 grams/yr exposure 

Approximately 12 seconds 

Minimum sensitivity in polluted ambience 

1 gram/year fixed; 3 grams/year moving 

Calibration frequency 

Check annually with calibrated leak source 

Summary of Contents for 69336

Page 1: ...4 YELLOW JACKET ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor Design Certified to meet SAE J2791 for R 134a Made in U S A 99 Washington Street Melrose MA 02176 Phone 781 6...

Page 2: ...ctors makes them easy to use in close areas and extendable into hard to reach areas Introduction Features Advanced digital SmartAlarm leak size indicator AccuProbe UV Flashing visual alarm indicator a...

Page 3: ...w located on the bottom of the detector and remove door 2 Install 4 AA alkaline batteries observing the proper battery polarity as labeled inside the battery compartment and shown above 3 Reinstall th...

Page 4: ...dio alarm may not sound but the SmartAlarm may show a high num ber indicating that the leak is large The maximum value displayed once the source of the leak is located indicates the leak size This val...

Page 5: ...eases in frequency Adjusting the sensitivity levels To choose another sensitivity level press the Sensitivity button The LED below each level will change indicating the new setting The leak detector w...

Page 6: ...as shown to replace the filter For optimum performance replace filter whenever it becomes visibly dirty with grease or oil or every 2 3 months depending on use Note Never clean dirty filters with a s...

Page 7: ...ndard bottle 69383 Sensor and filter 69384 Sensor filters package of 5 69385 Leak standard bottle 69386 A C Adapter Input 115V 60Hz UL listed 69380 A C Adapter EU UK Plug Input 230V 50Hz CE T V Approv...

Page 8: ...Carburetor Cleaner when wet Y Yes 24 MONTH LIMITED WARRANTY Ritchie Engineering guarantees YELLOW JACKET AccuProbe Leak Detectors to be free of defective material and workmanship that would affect the...