yellow jacket 61040 Manual For Operation Download Page 1

Heat Pump Kit 5/16” 
61040

Manual for Operation 

OMNI

 Vacuum Gauge Operating Instructions:

1.  Press the ON/OFF button to power on the gauge.
2.  To manually power off the gauge, press and hold the ON/OFF button until 

the screen displays the “YJ” logo.

3.  To change a setting: 

•  Tap the corresponding button to highlight the current setting
•  Continue to tap this button until the desired value is displayed
•  Press and hold this button to confirm the new setting – the highlighting 

will disappear when the setting has been confirmed

DISPLAY:

 Select from several notification options.  To change the back-

ground, press and hold for three seconds to inverse LCD mode.

ON/OFF: 

Power on and off, select from four different auto-off settings.

TARGET

UNITS

DISPLAY

ON/OFF

*TARGET

 - Select from five 

preset vacuum level targets.

*UNITS

 - Select from four 

different vacuum units.

Auto-Off Timer

(in minutes)

Target Vacuum 

Level 

Audio 

Notification

Notification

Icon

Vacuum 

Unit 

Vacuum Level 

(displays bar 

graph until deep vacuum reached)