![Yeastar Technology TA1610 User Manual Download Page 26](http://html1.mh-extra.com/html/yeastar-technology/ta1610/ta1610_user-manual_909649026.webp)
TA1610 User Manual
26/62
Routes Settings
After connecting Yeastar TA1610 gateway with the VoIP server, you need to configure
the routes settings on TA1610 to route the calls through the gateway. In this chapter,
we introduce the following sections:
IP->Port
Configure IP->Port routes to control calls from your SIP server to TA1610 FXO ports.
Click
“Edit” to check the route details, there are two modes for you.
1) Simple Mode
Choose
“Yes” for Simple Mode, the simple mode configuration page appears as
below.
Figure 5-1 Simple Mode Route
Table 5-1 Description of Simple Mode Route
Items
Description
Route Name
Define the route name.
Call Source
Choose the trunk or trunk group for the incoming
calls.
Call Destination
Choose the trunk or trunk group to route the incoming
calls to.
Hotline
Dial the number directly, The dial pattern is ignored.