background image

2018-02-14 

 

 

 
6)

 

It is recommended to have a Static IP Address assigned to this device, as it will need to be 
entered on the 8036 and/or 8039. Save the changes 
 

 

 

Configuring Algo 8039 SIP Video Intercom

 

 

1)

 

To configure the 8039, open an empty web browser, enter the device’s IP address in the 
address field, and press Enter 

2)

 

To  find  the  device’s  IP  address,  please  refer  to  the  user  guide  available  at:

 

http://www.algosolutions.com/8039/guide

 

    

 

 

 

3)

 

In the web interface, enter the password to log in (default password is algo

4)

 

Click on Basic Settings tab and then SIP tab. To register the 8039 with the SIP Server enter 
the domain name or IP address in the SIP Domain (Proxy Server) field. Enter a unique SIP 
Extension
Authentication ID and Authentication Password. Lastly, enter the Extension 
to Dial
 (this is dialed when Call button is pressed). At the bottom of the screen click Save  
 

Summary of Contents for T58V

Page 1: ......

Page 2: ...Contents Introduction 3 Before You Begin 3 Get Help 3 Scenario 4 Configuring Yealink T58V 4 Configuring Algo 8061 IP Relay Controller 5 Configuring Algo 8039 SIP Video Intercom 6 Configuring 8036 SIP...

Page 3: ...y phone multi tenant gate or entrance guest service and visitor assistance kiosk For further User Guide information please refer to 8036 SIP Multimedia Intercom 8039 SIP Video Intercom or 8061 IP Rela...

Page 4: ...ral 2 To access the configuration panel open an empty web browser enter the device s IP address in the address field and press Enter 3 In the web interface enter the username and password to log in de...

Page 5: ...uide available at http www algosolutions com 8061 guide 3 In the web interface enter the password to log in default password is algo 4 There is no need to do a separate SIP Server registration in this...

Page 6: ...vice s IP address please refer to the user guide available at http www algosolutions com 8039 guide 3 In the web interface enter the password to log in default password is algo 4 Click on Basic Settin...

Page 7: ...2 14 5 Navigate to Basic Settings tab then Door Control tab Enter the IP address Network Door Controller Address and password Network Door Controller Password assigned to the 8061 previously Save the...

Page 8: ...In the web interface enter the password to log in default password is algo 4 Click on Basic Settings tab and then SIP tab To register the 8036 with the SIP Server enter the domain name or IP address...

Page 9: ...9 2018 02 14 6 To configure the user interface buttons and functions please see the Quick Start guide available at www algosolutions com 8036docs...

Reviews: