background image

服务热线:

400-666-9216 

 

bonding

when two windowsare very close to each other, the software will 

automatically bonding two windows, off this functionyou can place the windows 

anywhere you want to place at.

 

 

Fig36    Connection WIndow

 

1.6 Parameters Sending 

When set up is completed, click "send"on the lower right corner.   

 

Fig37    Connection

 

8  MDEA2FAST FAQ 

FAQs 

Judgment and correction 

PW indicator is on, WK 

indicator does not blink 

1. The PW indicator off indicating that there is a problem with the 

power input 

http://www.ydeachn.com/

 

Add: Room 901, Building A, Block #5, Skyworth Inno Valley, No.8 Tangtou 1

st

 Rd., Shiyan,Bao’an  District, 

Shenzhen, P.R. China ; 

31 

Summary of Contents for MDEA2FAST

Page 1: ...r any problem during the use of this manual or you have a suggestion to us please contact us according to the contact manner on the manual We will do our best to help with your problem and we would like to thank you in advance for any suggestions from you The copyright of this document is belonging to Shenzhen YDEA Technology Co Ltd and no person or entity are allowed to reproduce or extract the c...

Page 2: ...stem Signal Connection Diagram 10 6 2 System specifications 10 7 MDEA2FAST Software Operation 11 7 1 Introduction to basic operation 11 7 2 Menu Bar Introduction 15 7 3 Shortcut menu bar 21 7 4 Debugging 24 8 FAQ 31 9 Installation Dimensions 32 Version Rev 2 0 0 Date 2017 02 15 http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shen...

Page 3: ...ding This device is connected to the earth by the earth wire of the power supply Please make sure the earth wire socket Electromagnetic interference This device should be away from magnets motors and transformers Moisture proof Please put the device in a dry and clean i t If li id i d l th l Away from flammable and explosive dangerous goods It is forbidden to immerse any liquid or metal parts into...

Page 4: ...aying it s with video processor and LED controller and compatible with LED synchronous asynchronous system At the same time it s with competitive price With this system can help customers to simplify the system structure reduce the cost of control MDEA2FAST has solved the problem of complex system structure various of external equipment single function high control cost difficult system management...

Page 5: ...a PC host to achieve local playback the integrated hardware codec module can support 720p HD video decoding and playback can play the local contents that saved in the hard disk U disk Low control cost MDEA2FAST is with very competitive price less peripheral equipment can help customers achieve lower control costs Better safety performance MDEA2FAST is based on the common system platform stable per...

Page 6: ...ems Description HDMI X1 Support HDMI1 3 above 1280 720 60hz USB X2 for mouse keyboard U disc Audio X1 3 5mm audio interface LED Video Interface X4 each socket can support output mode with 64 960 128 480 256 240 512 120 1024 60 each socket can be adjusted within 1024 600 S W Configuration Items Description O S Andriod 4 2 2 Playing S W Internal Electrical Indicators Items Description Power Input DC...

Page 7: ... 5 HDMI Interface Used for connecting monitor for debugging purpose 6 3 5mm earphone Interface Used for connecting earphone or sound system 7 Button 1 Used for Wi Fi reset and system recovery Long press 3 seconds for Wi Fi reset press Output Signal 4 Output Signal 2 Output Signal 3 Output Signal 1 http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan ...

Page 8: ...ystem only support DC5V USB2 Interface This interface is used to update the firmware USB1 Interface This interface supports USB device access such as USB disk mouse keyboard and other USB device HDMI Output HDMI output Supports an external HDMI DVI interface monitor to monitor the running status of the Mdea system Audio Output Audio output support 3 5 audio interface LED Video Output Interface LED...

Page 9: ...ftware is faulty you can use this button to restore all the software to the factory initial state The steps to restore the factory are as follows Press and hold the reset key power on the unit wait for 7 seconds release the reset button MDEA2FAST will restore the factory mode Hotspot reset Mainly used for MDEA2FAST in normal operation but cannot find the hot spots long press the reset button for 2...

Page 10: ...iving card distinguishes the input and output the signal end is marked as the IN and OUT 3 Use the OUT port of the receiving card to connect to the IN port of the next receiving card 4 We can use WIFI or MDEA2FAST hot spots to achieve wireless debugging screen with a computer MDEA2FAST hotspot is MDEA2FAST system automatically generated 5 When many MDEA2FAST devices are connected to the same LAN a...

Page 11: ...Mdea edition means this is Mdea system debugging according to the actual need to select a corresponding system after each choose of a different system the software will automatically restart the upper left corner of the software displays the currently selected system at the same time as shown in the figure below Fig1 Software Interface 2 For MDEA2FAST we just simply select C5M_Mdea is okay http ww...

Page 12: ...ns functional area operating area menu shortcut menu area 7 1 2 Basic operation introduction 1 Test network connection switch the s w to network communication mode then the computer wireless network connec with Mdea hotspot Fig3 Connection Setting http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 12 ...

Page 13: ...rial port implementation So the computer can only be connected through WIFI network or Mdea hot spot tp achieve wireless network control 3 The Mdea system under hotspot mode it will generate a hot spot with a suffix name __host Click the refresh button to view the connection to the Mdea hotspot As shown in figure The connection is successful http www ydeachn com Add Room 901 Building A Block 5 Sky...

Page 14: ...ck the IP address with the arrow pointing then click ok in the box At this time the software is well connected to Mdea system Fig6 Network Communication If the control software is not connected normal the s w shows the connection fail need to connect again http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 14 ...

Page 15: ... Mdea system hotspt status is normal 7 2 Menu Bar Introduction 7 2 1 Document Fig 7 Document Open Used to open previously saved screen parameters Save Used to save currently parameters for next time easy use Exit Click to quit the s w 7 2 2 Functions http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 15 ...

Page 16: ...User Manual Fig 8 Functions Brightness can adjust the global brightness current gain color temperature http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 16 ...

Page 17: ...ates you can change the value of red green and blue color temperature range to set the color temperature you need Automatic brightness adjustment _Light Sensor MDEA system do not support the brightness adjustment yet Automatic brightness adjustment _DMX Check out MDEA brightness http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District She...

Page 18: ...t update particular case please contact technical support staff Dot by dot Correction Point by point correction according to actual need Mdea system temporarily does not support correction Gamma adjust different gray level according to your request Fig10 Gamma Setting Grayscale values range 8 16Bit The transition of Gamma value range 0 000 3 00 used to adjust the Gamma curve http www ydeachn com A...

Page 19: ...e current Settings to the controller The register Setting You can set the value of the register according to your demonds all the values will be set before the screen goes to market customers do not need to operate Fig11 Register Setting Logo import Can import Logo to the little LED display behind the Screen EDID Configuration MDEA2FASTdo not have DVI signal input so no this function Characteristi...

Page 20: ... between computers and C5 system the computer is connect to the C5 systemthrough a serial port 2 Network communication is used for communication between computer and MDEA2FAST system a computer can communicate with MDEA2FAST when they are within the same local area network LAN Fig12 Communication Setting Language used to set the software to Chinese simplified or traditional display or English Fig1...

Page 21: ...About Click on the menu can view the version of installed software it can help the user to easy communicate with the technical personnel from display manufacturers Fig14 S w version 7 3 Shortcut menu bar http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 21 ...

Page 22: ...file convenient to load directly for next time use click on this button to adjust the brightness current gain and color temperature Note 1 The current gain setting is hidden by default need to enter the password under the window to displayed the password is ydea 2 PC software default current gain maximum adjust to 172 input pincode 0000 to http www ydeachn com Add Room 901 Building A Block 5 Skywo...

Page 23: ...isplay on off During manual and automatic connectivity click on the icon you can cancel the connection Check the control system version which currently connected to the computer Note this shortcut button can query the current version of the control system include controller version receiving card version when using CTRL mouse wheel to expand the view of the window click the icon to return to the i...

Page 24: ...ort output of MDEA2FAST system can support up to 1024 600 pixels 2 The software default to choose P1 no need to change 1 2Port adding Click on the Port mode to enter the interface Fig27 Port adding http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 24 ...

Page 25: ... size is pixel density of single micro receive card Number transverse loading screen number X and vertical loading screen number Y Note Numbers here refers to receiving cardthat one distributor takes Connection you can set the port connection way there are eight kinds of connection mode for your choice if connection way is irregular you can click edit to enter complex mode Settings http www ydeach...

Page 26: ...me the body size the default direction of the screen body size blocks rotate after the actual carrying blocks of X direction Y direction of the blocks choose connection mode and then choose the rotation Angle and then click add and then the display will automatically change 3 For example a screen body size is 96 16 power supply box on the right if you need the vertical display power supply box on ...

Page 27: ... add and then you will see a single screen size becomes X16 Y96 automatically Fig30Mode adding Complex Patterns http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenzhen P R China 27 ...

Page 28: ... serial numberon the right side window it s the physical address of the receive card the default is 1 Coordinates used to modify the coordinates of each module to showing a different position Cancellation Clearance can easily modify the signal connection mode Done After finish setting change click Done 1 3 Port No http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangt...

Page 29: ...freely it can move within 1024 600 points 1 4 Position fine adjustment Window position can be drag within load points scope empty area equivalent to the location of the monitor screen of a computer also you can set window starting coordinates by the Position fine adjustment functionon the lower left corner Fig33 Connection window http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno V...

Page 30: ...ck on window to choose how to arrange the connection Fig35 Connection window Selected the window has been well set and then click the right mouse button can pop up the following Settings Delete window Delete current window Clear window Clear all the windows under a port of the master set Clear connection Clear all the connections under a port of the master set http www ydeachn com Add Room 901 Bui...

Page 31: ...ndow 1 6 Parameters Sending When set up is completed click send on the lower right corner Fig37 Connection 8 MDEA2FAST FAQ FAQs Judgment and correction PW indicator is on WK indicator does not blink 1 The PW indicator off indicating that there is a problem with the power input http www ydeachn com Add Room 901 Building A Block 5 Skyworth Inno Valley No 8 Tangtou 1st Rd Shiyan Bao an District Shenz...

Page 32: ...of the control system is sent correctly Signal connection is normal while the screen is black 1 Check the brightness of the transmission is zero or not in the s w 2 Check the host computer software if screen body switch is unlocked The computer can not connect to MDEA2FST 1 Check whether the MDEA2FST hotspot status is normal and whether the computer side wireless network is connected to this hotsp...

Reviews: