Yatai Inverter YTB-S-LT User’s Manual
5.
Parameters and Function Codes
YTB-S-LT Series specific winding converter provides users with the following function parameters. By modifying
the value of these parameters, the frequency converter can meet various requirements of users.
5.1
Zoom Table of the Parameters and Function Codes
Table 5-1 Table of the Parameters and Functions Codes
Factory
Function
Illustration of
Setting Range
Unit
Change
Value
Code
Function
0-00 User
Password
0
~
9999
Non 8
×
0-01 Acceleration
Time
0.1
~
300.0
Second 3.0
×
0-02 Deceleration
Time
0.1
~
300.0
Second
3.0
×
0-03
Carrier Frequency
2
~
10
KHz
3
×
0-04
Compensation Torque
Curve
1
~
18
Non 4
×
0-05
Setting of the Length
100
~
9999
Non 1000
×
0-06
Type of Frequency
Adjusting
0:Frequency decrease
progressively Control
1:PI Control
2:Frequency Sway Control
3:Frequency increase
progressively Control
4
:
Constant Tension
Non 0
×
D
ist
ric
t o
f B
as
ic
W
in
din
g P
ar
am
ete
r
Restore the Factory
Values
0-07
0: No 1: Yes
Non
0
×
0-08 Preservation
Non
0
×
Display Selection of
0: Display Velocity
0-09
the Extra-feeding
1: Display Operating
Non 0
×
Parameter
Frequency