Station-number Setting
A station number is set by both the S1-3 DIP switch and the S2 rotary switch. Station num-
bers from 21 to 3E are valid. Although 20 or 3F can be set as a station number, do not use
these settings because they will be faulty.
S1-3:Set the 10’s digit of the station number.
OFF = 2 (2X)
ON = 3 (3X)
S2: Set the 1’s digit of the station number.
0 = 0 (X0)
1 = 1 (X1)
x
x
x
x
F = F (XF)
Switch Setting and Station Number
SI-3
S2
Station
Number
S1-3
S2
Station
Number
OFF
0
Fault
ON
0
30
OFF
1
21
ON
1
31
OFF
2
22
ON
2
32
OFF
3
23
ON
3
33
OFF
4
24
ON
4
34
OFF
5
25
ON
5
35
OFF
6
26
ON
6
36
OFF
7
27
ON
7
37
OFF
8
28
ON
8
38
OFF
9
29
ON
9
39
OFF
A
2A
ON
A
3A
OFF
B
2B
ON
B
3B
OFF
C
2C
ON
C
3C
OFF
D
2D
ON
D
3D
OFF
E
2E
ON
E
3E
OFF
F
2F
ON
F
Fault