background image

VS-616PC5/P5
Option Instruction Manual

Isolated 4-20mA Output Monitor Card CM-B2/P

Summary of Contents for VS-616PC5 Series

Page 1: ...VS 616PC5 P5 Option Instruction Manual Isolated 4 20mA Output Monitor Card CM B2 P ...

Page 2: ...minate the possibility of static charge if present affecting the card Failure to observe this precaution may result in equipment damage NOTICE Printed November 1996 The information contained within this document is the proprietary property of Yaskawa Electric America Inc and may not be copied reproduced or transmitted to other parties without the expressed written authorization of Yaskawa Electric...

Page 3: ... option card please specify the inverter model and code number Description NAME CODE NUMBER FUNCTIONS Isolated Monitor Card CM B2 P 73600 DO12X Converts analog monitor signals 0 to 10V to isolated signals 0 to 10V 4 to 20mA or 0 to 20mA CM B2 P 73600 DO120 Grounding lead wire connected to terminal E G of inverter control board E Terminal block TB1 for isolated signal output Analog monitor signals ...

Page 4: ...cated on each side of the cover and lift the cover upward from the rear of the cover Refer to the VS 616PC5 P5 User s Manual YEA TOA S616 12 if necessary 5 Check that the indicator CHARGE LED is OFF indication that power is OFF 6 Place the Isolated Monitor Card onto the four 4 stand off posts in the control board aligning the Isolated Monitor Card s connector with the control board s 2CN connector...

Page 5: ... 2 Installation of Isolated Monitor Card CM B2 P Connector terminal FRONT VIEW CM B2 P SIDE VIEW Stand Off Posts 4 CM B2 P TB1 TB2 1 HDR1 GND 73600 D0120 CODE NO TP1 Refer to Fig 3 1 1 1 12 S1 S2 AM AC S3 Fig 3 Output Signal Configuration 3 6 9 2 5 8 1 4 7 JUMPER for HDR1 HDR1 3 6 9 2 5 8 1 4 7 HDR 1 Configures Output Signal at TB1 Note The three jumpers on the HRD1 are used to configure the outpu...

Page 6: ...gnals Connect the wire as shown in Fig 5 to prevent noise interference Failure to observe these precautions may result in equipment malfunctions L1 R L2 S L3 T IM U T1 V T2 W T3 VS 616 PC5 P5 E G AC AM 2 1 2CN 2CN E Isolated Monitor Card CM B2 P Fig 4 Interconnection Diagram 250 P Current Output TB1 TP1 TB2 12 CAUTION Shielded Sheath Armor Fig 5 Shielded Wire B C A A NEVER connect the wire s shiel...

Page 7: ...re as listed in the following table Stripping TB1 and TB2 Wires for Connection The following figure shows the correct length of insulation to be stripped in order to connect the wire to terminal blocks TB1 and TB2 Cable Selection 1 Cable that is too heavy exerts pressure on the option card and may cause failure 2 Cable too thin may cause a poor connection or may prematurely break External Function...

Page 8: ... Woods Cumbernauld Scotland G68 9LD U K Phone 1236 735000 Fax 1236 458182 YASKAWA ELECTRIC KOREA CORPORATION Paik Nam Bldg 901 188 3 1 Ga Euljiro Joong Gu Seoul Korea Phone 02 776 7844 Fax 02 753 2639 YASKAWA ELECTRIC SINGAPORE PTE LTD Head Office CPF Bldg 79 Robinson Road 13 05 Singapore 0106 SINGAPORE Phone 221 7530 Telex 87 24890 YASKAWA RS Fax 224 5854 Service Center 221 Henderson Road 07 20 H...