n

Web browser is running

Click [Settings] on the blue splash screen, then enter the user name "admin" and

the password "admin".

n

The "System Settings" in 

User Mode 

is accessible remotely via web browser of the

PC, enter 

https://<HMI_IP_address>

.

VIPA HMI

Deployment

Commissioning > System Settings

HB160 | TP-cloud | HA1-L1A41-0 | en | 18-02

 

25

Summary of Contents for VIPA HMI TP110-CL

Page 1: ...TP cloud HA1 L1A41 0 Manual HB160 TP cloud HA1 L1A41 0 en 18 02 VIPA HMI cloudPanel TP110 CL www vipa com en service support manuals...

Page 2: ...HA1 L1A41 0_000_TP110 CL 1 EN 2018 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Page 3: ...ployment 17 3 1 Installation 17 3 2 Commissioning 18 3 2 1 Web browser 18 3 2 2 System Settings 21 3 2 3 Firmware update 29 3 3 Connection to a PLC system 30 4 Installation Guidelines 31 4 1 Basic rul...

Page 4: ...ive purchase contract Hereby VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions Conformity is indicated by the CE marking...

Page 5: ...1 0 0 Linux 3 12 The manual is targeted at users who have a background in automation technology The manual consists of chapters Every chapter provides a self contained description of a specific topic...

Page 6: ...Supplementary information and useful tips VIPA HMI General About this manual HB160 TP cloud HA1 L1A41 0 en 18 02 6...

Page 7: ...that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices and m...

Page 8: ...Cortex A8 1GHz n Flash memory 4GB RAM 512MB DDR n RS232 RS422 RS485 interface not available for WebVisu projects USB A and Ethernet interface n Robust plastic case n Display resolution 600 x 1024 1024...

Page 9: ...tive area Touch Screen 1 USB A interface USB 2 0 2 RJ45 jack for Ethernet communication LAN 3 RS232 RS422 RS485 interface COM 4 Slot for DC 24V voltage supply Front view Bottom view VIPA HMI Hardware...

Page 10: ...ellow Description on off no link blinks on 100Mbit s link blinks off 10Mbit s link 9 pin SubD plug n Interface is compatible to the COM interface of a PC n Logical signals as voltage levels n Point to...

Page 11: ...this you find an according DC 24V slot at the bottom Connect power supply on page 17 2 3 3 Memory management The following memory systems are available for the cloudPanel n 512MB work memory RAM n 4G...

Page 12: ...are only guaranteed when the following is observed Material thickness at the mounting cut out 1 5 6mm The deviation from the plane for the panel cut out is 0 5mm This condition must be fulfilled for...

Page 13: ...tion voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14...

Page 14: ...single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data Order no HA1 L1A41...

Page 15: ...232 RS422 RS485 COM1 connector Sub D 9 pin male Serial COM2 COM2 connector Number of USB A interfaces 1 USB A connector USB A host Number of USB B interfaces USB B connector Number of ethernet interfa...

Page 16: ...ensions Front panel 282 mm x 197 mm x 6 mm Rear panel 268 mm x 183 mm x 29 mm Installation cut out Width 271 mm Height 186 mm Minimum 1 5 mm Maximum front panel thickness 6 mm Net weight 840 g Weight...

Page 17: ...loudPanel into the openings The screws should point in the direction of the front panel 3 Screw the screws from the other side with the crosstip screwdriver 5 n For the cabling of the DC 24V power sup...

Page 18: ...g the control cabinet or desk there are parts with pos sible dangerous voltage available For all signal connections only screened cables are permitted Signal cables must not be let within the same cab...

Page 19: ...System Settings interface of the cloudPanel Service Support With active internet connection this button takes you directly to VIPA Service Support Use the button in the upper right corner of the brows...

Page 20: ...llback to default URL Default URL Setting the address of the homepage default VIPA splash screen file mnt data WWW index html Last visited Page Activate deactivate the display of the last visited page...

Page 21: ...nu Use navigation menu on the left side of the screen to browse through the available options With the following menu items Here you can select a language for the System Settings menu The following la...

Page 22: ...IP address of the Ethernet interface Network mask and gateway You have to disable DHCP Go to Edit In the cloudPanel you have to set an IP address that is in the same IP range as the web server Here y...

Page 23: ...play set the time of the auto matic backlight timeout and select panel orientation 90 180 270 and 360 You can also calibrate the Touch Display here n Here you can restart the cloudPanel in User Mode o...

Page 24: ...stem Mode includes all options available in User Mode and offers in additions commands dedicated to system upgrade and recovery not available when running in User Mode n Default Mode The Default Mode...

Page 25: ...creen then enter the user name admin and the password admin n The System Settings in User Mode is accessible remotely via web browser of the PC enter https HMI_IP_address VIPA HMI Deployment Commissio...

Page 26: ...Select Restart Config OS to reboot in System Mode n Normal operation Web Browser is running 1 Click on Settings on the blue splash screen to start System Settings in User Mode 2 Select Restart Config...

Page 27: ...ault mode allows Restore Factory Settings this mode is available via Tap Tap sequence and can be accessed also when cloudPanel is facing a software failure Tap Tap consists in a sequence of several to...

Page 28: ...ter SYSTEM SETTINGS 2 Press on touch screen TOUCHSCREEN CALIBRATION will be highlighted in yellow hold pressed for few seconds until touchscreen calibration procedure starts 3 Follow the instructions...

Page 29: ...update process and unzip the content in the root directory of the USB stick 1 Connect the cloudPanel to the power supply The cloudPanel starts with the VIPA splash screen 2 Open the System Settings i...

Page 30: ...red IP address of the Ethernet channel and is called by entering this IP address in the address bar of the Web browser Per default port 8080 is used for http http IP address PLC 8080 n The cloudPanel...

Page 31: ...nt ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free an...

Page 32: ...n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following basi...

Page 33: ...ial EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrical op...

Page 34: ...even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts have t...

Page 35: ...ups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed in...

Page 36: ...equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is connected...

Page 37: ...over Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to att...

Page 38: ...iode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutral co...

Page 39: ...n grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunches...

Reviews: