4.3 Parameter data
Via parameterization you may define among others:
n
Parameters of the SSI encoder (see data sheet of the encoder)
n
Operating mode of the module (master mode/listening mode)
n
Activation diagnostic interrupt
DS - Record set for access via CPU, PROFIBUS and PROFINET
IX - Index for access via CANopen
SX - Subindex for access via EtherCAT with Index 3100h + EtherCAT-Slot
More can be found in the according manual of your bus coupler.
Name
Bytes
Function
Default
DS
IX
SX
DIAG_EN
1
Diagnostic interrupt
1
00h
00h
3100h
01h
IDLE
2
Pause time
0C00h
80h
3101h...
3102h
02h
BAUD
2
Transmission rate
0180h
80h
3103h...
3104h
03h
CRES
1
reserved
00h
80h
3105h
04h
NORM
1
Normalization
00h
80h
3106h
05h
LGTH
1
Bit length encoder data
18h
80h
3107h
06h
MODE
1
SSI mode
1Eh
80h
3108h
07h
CRES
3
reserved
00h
80h
3109h...
310Bh
08h ...
0Ah
SSI_EN
1
SSI function
00h
80h
310Ch
0Bh
1) This parameter may only be transferred at STOP state.
Byte
Bit 7 ... 0
0
Diagnostic interrupt
n
00h = disable
n
40h = enable
n
Here you activate res. de-activate the diagnostic function.
With
pause
also known as tbs (time between sends), you may indicate the waiting period,
which is to be kept by the module between two encoder values, so that the encoder may
preprocess his value. These data may be found in the data sheet of your encoder.
Parameters
DIAG_EN Diagnostic inter-
rupt
IDLE Pause
VIPA System SLIO
Deployment
Parameter data
HB300 | FM | 050-1BS00 | en | 20-40