3.10 Control I/O Connections
112
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
◆
Power Supply Inputs Instead of the Safe Disable Feature (CIMR-UA
/UD
/UT
)
to wire the input terminals for an external power supply instead of the Safe Disable feature.
Figure 3.53
Figure 3.52 Power Supply Inputs Instead of the Safe Disable Feature (CIMR-UA
/UD
/UT
)
◆
Sinking/Sourcing Mode Selection for Safe Disable Inputs (CIMR-UB
)
Use jumper S3 on the terminal board to select between Sink mode, Source mode or external power supply for the Safe
Disable inputs H1 and H2 as shown in
(Default: Source mode, internal power supply.)
Figure 3.54
Figure 3.53 Jumper S3 (CIMR-UB
)
Table 3.19 Safe Disable Input Sink / Source / External Power Supply Selection (CIMR-UB
)
Drive Internal Power Supply
External 24 Vdc Power Supply
Sinking Mode
Sourcing Mode
Sink Mode
Source Mode
IP24 V
(24 V)
SC
H1
H2
HC
S8
24 V
IP24 V
(24 V)
SC
H1
H2
HC
S8
24 V
M1 M2 M5
M3 M6 M4
E(G) HC H1 H2 DM+ DM- IG R+ R- S+ S-
V+ AC V- A1 A2 A3 FM AM AC MP RP AC
Jumper S3
Terminal H1/H2
Sink/Source Sel.
24 Vdc
H1
H2
HC
Jumper S3
24 Vdc
H1
H2
HC
External
24 Vdc
Jumper S3
24 Vdc
H1
H2
HC
Jumper S3
24 Vdc
H1
H2
HC
External
24 Vdc
Jumper S3