n
Digital Operator Remote Installation
Digital Operator Dimensions
S/N : J007XE273710001
90
78
60
7.9
50
12.2 1.6
44
15
Installation holes (2-M3 screws, depth 5)
minimum
Unit: mm
Figure 2.12 Digital Operator Dimensions
Installation Types and Required Materials
The digital operator mounts to an enclosure two different ways:
•
External/face-mount
installs the operator outside the enclosure panel
•
Internal/flush-mount
installs the operator inside the enclosure panel
Table 2.3 Digital Operator Installation Methods and Required Tools
Installation
Method
Description
Installation
Support Sets
Model
Required Tools
External/
Face-Mount
Simplified installation with
the digital operator is
mounted on the outside of
the panel with two screws.
–
–
Phillips screwdriver
(#1)
Internal/
Flush-Mount
Encloses the digital
operator in the panel. The
front of the digital operator
is flush with the outside of
the panel.
Installation Support Set A
(for mounting with screws
through holes in the panel)
EZZ020642A
Phillips screwdriver
(#1, #2)
Installation Support Set B
(for use with threaded studs
that are fixed to the panel)
EZZ020642B
Phillips screwdriver (#1)
Wrench (7 mm)
NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during installation and project
construction. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation.
Remove the temporary cover before drive start-up, as the cover will reduce ventilation and cause the drive to overheat.
External/Face-Mount
1.
Cut an opening in the enclosure panel for the digital operator as shown in
2.
.
Digital Operator
M3 x 6
Phillips recessed
pan head machine screw x 2
Enclosure panel
Unit: mm
Figure 2.13 External/Face-Mount Installation
2.2 Mechanical Installation
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
65
2
Mechanical Installation
Summary of Contents for U1000 iQpump Drive