A.5 Drive Derating Data
The drive can be operated at above the rated temperature, altitude, and default carrier frequency by derating the drive capacity.
u
Rated Current Depending on Carrier Frequency
The table below shows the drive output current depending on the carrier frequency settings.
Use the data in the following tables to linearly calculate output current values for carrier frequencies not listed.
Table A.10 Three-Phase 200 V Class Carrier Frequency and Current Derating
Drive Model
Setting
Range
Rated Current [A]
Normal Duty Rating (ND)
Heavy Duty Rating (HD)
4 kHz
6 kHz
8 kHz
10 kHz
4 kHz
6 kHz
8 kHz
10 kHz
2
o
0028
4 to 10 kHz
28
25
22
20
22
20
18
15
2
o
0042
4 to 10 kHz
42
38
34
29
28
25
22
20
2
o
0054
4 to 10 kHz
54
49
43
38
42
38
34
29
2
o
0068
4 to 10 kHz
68
61
54
48
54
49
43
38
2
o
0081
4 to 10 kHz
81
73
65
57
68
61
54
48
2
o
0104
4 to 8 kHz
104
94
83
—
81
73
65
—
2
o
0130
4 to 8 kHz
130
117
104
—
104
94
83
—
2
o
0154
4 to 6 kHz
154
139
—
—
130
117
—
—
2
o
0192
4 to 6 kHz
192
173
—
—
154
139
—
—
2
o
0248
4 kHz
248
—
—
—
192
—
—
—
Table A.11 Three-Phase 400 V Class Carrier Frequency and Current Derating
Drive Model
Setting
Range
Rated Current [A]
Normal Duty Rating (ND)
Heavy Duty Rating (HD)
4 kHz
6 kHz
8 kHz
10 kHz
6 kHz
8 kHz
10 kHz
4
o
0011
4 to 10 kHz
11
9.9
8.8
7.7
9.6
8.6
7.7
6.7
4
o
0014
4 to 10 kHz
14
13
11
9.8
11
9.9
8.8
7.7
4
o
0021
4 to 10 kHz
21
19
17
15
14
13
11
9.8
4
o
0027
4 to 10 kHz
27
24
22
19
21
19
17
15
4
o
0034
4 to 10 kHz
34
31
27
24
27
24
22
19
4
o
0040
4 to 10 kHz
40
36
32
28
34
31
27
24
4
o
0052
4 to 10 kHz
52
47
42
36
40
36
32
28
4
o
0065
4 to 10 kHz
65
59
52
46
52
47
42
36
4
o
0077
4 to 10 kHz
77
69
62
54
65
59
52
46
4
o
0096
4 to 8 kHz
96
86
77
—
77
69
62
—
4
o
0124
4 to 8 kHz
124
112
99
—
96
86
77
—
4
o
0156
4 to 6 kHz
156
140
—
—
124
112
—
—
4
o
0180
4 to 6 kHz
180
162
—
—
156
140
—
—
4
o
0216
4 kHz
216
—
—
—
180
—
—
—
4
o
0240
4 kHz
240
—
—
—
216
—
—
—
4
o
0302
4 kHz
302
—
—
—
240
—
—
—
4
o
0361
4 kHz
361
—
—
—
302
—
—
—
4
o
0414
4 kHz
414
—
—
—
361
—
—
—
4
o
0477
3 kHz
477
—
—
—
414
—
—
—
4
o
0590
3 kHz
590
—
—
—
477
—
—
—
4
o
0720
3 kHz
720
—
—
—
590
—
—
—
4
o
0900
3 kHz
900
—
—
—
720
—
—
—
4
o
0930
3 kHz
930
—
—
—
900
—
—
—
<1> Carrier frequency is 3 kHz for models 4
A.5 Drive Derating Data
486
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual