4.4 Start-up Flowcharts
YASKAWA ELECTRIC
SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
85
S
ta
rt
-U
p Pr
og
ra
mmin
g
&
O
p
er
at
io
n
4
◆
Subchart A1: Simple Motor Setup with Energy Savings or Speed Search Using V/f
Mode
, Flowchart A1, describes simple motor setup for V/f control. This procedure illustrates using Energy Savings
and Speed Estimation Speed Search. V/f control can be used where rotational auto-tuning cannot be performed.
Figure 4.7
Figure 4.7 Simple Motor Set-Up with Energy Savings or Speed Search Using V/f Mode
◆
Subchart A2: High Performance Operation Using Open Loop Vector Motor Control
, Flowchart A2, describes Open Loop Vector Control for high-performance motor operation. This is
appropriate for applications requiring high starting torque, torque limits, and improved speed regulation.
Figure 4.8
Figure 4.8 Flowchart A2: High Performance Operation Using Open Loop Vector Motor Control
From
Flowchart
A
Set or verify the V/f pattern settings E1-
.
Energy Savings
(b8-01=1)
or
Speed Estimation
Speed Search
(b3-24=1)
enabled ?
Is the motor cable
longer than 50 m?
Perform Rotational Auto-Tuning
for V/f Control
(T1-01 = 3)
NO
YES
Perform Stationary Auto-Tuning for
terminal resistance (T1-01 = 2)
YES
NO
Return to
Flowchart
A
From
Flowchart
A
Possible for motor to
rotate during tuning? <1>
<1> Rotational tuning should
be performed with the
load disconnected
NO
YES
NO
Motor test report/ data
sheet available?
NO
YES
YES
Perform Rotating Auto-
Tuning (T1-01 = 0)
Is the motor cable
longer than 50 m?
Perform Stationary Auto-Tuning for
terminal resistance (T1-01 = 2)
Enter the data from the motor data
sheet to E2-
parameters.
Calculate necessary E2-
parameter data using the
nameplate information.
Return to
Flowchart
A