5.6 F: Option Settings
158
YASKAWA ELECTRIC
SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
■
F6-07: NetRef/ComRef Function Preselection Capability
Selects how multi-step speed inputs are treated when the NetRef command is set.
Setting 0: Multi-step speed operation disabled
If the NetRef command is selected, multi-step speed input frequency references are disabled (like Yaskawa F7 drives).
Setting 1: Multi-step speed operation enabled
Even if the NetRef command is selected, multi-step speed inputs are still active and can override the frequency reference
from the communications option (like Yaskawa V7 drives).
■
F6-08: Reset Communication Parameters
Determines whether communication-related parameters (F6-
) are reset when the drive is initialized using parameter
A1-03.
Setting 0: Do not reset parameters F6-
when the drive is initialized with A1-03
Setting 1: Reset F6-
when the drive is initialized with A1-03
Note:
F6-08 is not reset when the drive is initialized, but does determine whether initializing the drive with A1-03 resets the other
communication parameters F6-
.
■
F6-64 to F6-71: Dynamic Assembly Parameters (Reserved)
◆
CC-Link Parameters
Parameters F6-04, F6-10, F6-11, and F6-14 set up the drive to operate on a CC-Link network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card CC-Link Installation Manual and
Technical Manual.
◆
PROFIBUS-DP Parameters
Parameters F6-30 through F6-32 set up the drive to operate on a PROFIBUS-DP network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card PROFIBUS-DP Installation Manual
and Technical Manual.
◆
CANopen Parameters
Parameters F6-35 and F6-36 set up the drive to operate on a CANopen network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card CANopen Installation Manual and
Technical Manual.
◆
DeviceNet Parameters
Parameters F6-50 through F6-63 set up the drive to operate on a DeviceNet network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card DeviceNet Installation Manual and
Technical Manual.
No.
Parameter Name
Setting Range
Default
F6-07
NetRef/ComRef Function Preselection Capability
0, 1
0
No.
Parameter Name
Setting Range
Default
F6-08
Reset Communication Parameters
0, 1
0
No.
Parameter Name
Setting Range
Default
F6-64 to F6-71
Dynamic Assembly Parameters (Reserved)
0 to FFFFH
0