8 Communication Objects Overview
YASKAWA ELECTRIC
TOBP C730600 24D 1000-Series Option SI-S3/V, SI-S3/T Installation Manual
31
◆
Drives and Motion Profile Objects (DSP 402)
The drive supports the Drive and Motion Profile DSP 402 Velocity Mode. Before using the
Velocity Mode objects the following parameters have to be set up in the drive:
• The motor pole number must be set up in E2-04.
• The frequency reference and output frequency display unit has to be set to min
-1
by setting
parameter o1-03 = 2.
If these settings are not done properly, the Velocity Mode objects can not be used or deliver
wrong data.
Object Type
<1> YASKAWA specifies this object as the drive digital output monitor. (Input from the network)
<2> YASKAWA specifies this object as the drive digital inputs. (Output to the network)
Index (Hex)
Name
Common
Entries
60FD
Digital Inputs
60FE
Digital Outputs
Device
Control
6040
Controlword
6041
Statusword
6061
Modes of operation display
Velocity
Mode
6042
vl target velocity
6043
vl velocity demand
6044
vl control effort
6046
vl velocity min max amount
6048
vl velocity acceleration
6049
vl velocity deceleration
604A
vl velocity quick stop
604C
vl dimension factor
604D
vl pole number