background image

CompoNet

通信

V1000

オプションユニット

取扱説明書

形式

SI-M3/V

CompoNet

YASKAWA AC Drive-V1000 Option

Installation Manual

Type  SI-M3/V

To properly use the product, read this manual thoroughly and retain 
for easy reference, inspection, and maintenance. Ensure the end user 
receives this manual.

製品を安全にお使い頂くために,本書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。

MANUAL NO.  TOBP C730600 54A

Summary of Contents for SI-M3/V

Page 1: ...A AC Drive V1000 Option Installation Manual Type SI M3 V To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user receives t...

Page 2: ...prior written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high quali...

Page 3: ...et Installation Manual 3 Table of Contents 1 PREFACE AND SAFETY 4 2 PRODUCT OVERVIEW 9 3 RECEIVING 10 4 OPTION COMPONENTS 11 5 INSTALLATION PROCEDURE 16 6 RELATED PARAMETERS 28 7 TROUBLESHOOTING 31 8...

Page 4: ...ve or sole safety control Without exception all controls should be designed to detect faults dynamically and fail safely under all circumstances All systems or equipment designed to incorporate a prod...

Page 5: ...obtain the technical manual Customers in other areas should contact a Yaskawa representative Yaskawa Drive Yaskawa AC Drive V1000 Quick Start Guide The drive manuals cover basic installation wiring op...

Page 6: ...ns indicate safety messages in this manual Failure to heed these messages could cause fatal injury or damage products and related equipment and systems DANGER Indicates a hazardous situation which if...

Page 7: ...ing new copies of the manual contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover DANGER Heed the safety messages in this manual...

Page 8: ...permettre la decharge des condensateurs Pour repondre aux exigences s assurer que le neutre soit relie a la terre pour la serie 400V WARNING Read manual before installing Wait 5 minutes for capacitor...

Page 9: ...CompoNet is a communications link to connect industrial devices such as sensors and variable frequency drives as well as masters such as programmable controllers to a CIP network By installing the Co...

Page 10: ...tioning Contact your supplier if you have received the wrong model or the option does not function properly Option Package Contents Tools Required for Installation A Phillips screwdriver M3 metric 1 2...

Page 11: ...ng tabs C Option cover I Ground wire 2 1 Refer to Option LED Display on page 13 for details on the LEDs 2 The ground wire provided in the option shipping package must be connected during installation...

Page 12: ...1 06 in to the total depth of the drive Figure 2 Figure 2 Dimensions Communication Cable Connector The communication connector on the option is a 4 pin pluggable female connector This connector is th...

Page 13: ...e LEDs Table 3 Option LED States Pin Cable color Signal Description 1 Red BS Communications DC 24V 1 1 Not used with the CompoNet Option 2 White BDH Comm Data High 3 Blue BDL Comm Data Low 4 Black BS...

Page 14: ...being supplied Green ON Online communications established Device is online with connections in the established state I O connection is established with other nodes Green Flashing Online communication...

Page 15: ...ion MAC ID is set by drive parameter F6 40 MAC ID settings between 0 63 are considered a valid MAC IDs The option reads the MAC ID value from parameter F6 40 upon power up and upon a network reset Opt...

Page 16: ...ove the option cover while the power is on Failure to comply could result in death or serious injury The diagrams in this section may include options and drives without covers or safety shields to sho...

Page 17: ...e to comply may cause the application to operate incorrectly or damage the drive Do not operate damaged equipment Failure to comply may cause further damage to the equipment Do not connect or operate...

Page 18: ...move the front cover This drive front cover will be replaced by the option cover Cover removal varies depending on drive size DANGER Electrical Shock Hazard Do not connect or disconnect wiring while t...

Page 19: ...igure 5 for details Refer to Figure 6 for drive models CIMR V BA0006B to BA0018B 2A0008B to 2A0069B and 4A0001B to 4A0038B which require removing the terminal cover prior to removing the bottom cover...

Page 20: ...page 23 6 For IP20 NEMA Type 1 Enclosure models CIMR V A F loosen the screw on the front of the NEMA Type 1 terminal cover and remove it from the drive Refer to Figure 8 for details Refer to Figure 9...

Page 21: ...Figure 9 Remove the Terminal Cover on an IP20 NEMA Type 1 Drive Models CIMR V BA0006F to BA0018F 2A0008F to 2A0069F 4A0001F to 4A0038F 7 Loosen the screws attaching the NEMA Type 1 conduit bracket to...

Page 22: ...ng to Figure 11 and connect the drive side of the ground wire to the drive ground terminal Note The four different ground wires packaged with the option connect the option to different drive models Se...

Page 23: ...els CIMR V BA0006 to BA0018 2A0008 to 2A0069 and 4A0001 to 4A0038 reattach the terminal cover Refer to Figure 14 for drive models CIMR V BA0006 to BA0018 2A0008 to 2A0020 and 4A0001 to 4A0011 which re...

Page 24: ...igure 14 Terminal Cover Ground Wire Notch Models CIMR V BA0006 to BA0018 2A0008 to 2A0020 4A0001 to 4A0011 11 Pass the ground wire through the inside of the drive bottom cover and into the through hol...

Page 25: ...option to the drive case Figure 16 Figure 16 Connect the Option 13 Connect the ground wire at the option ground terminal Tighten the screw to 0 5 0 6 Nm or 4 4 5 3 in lbs using an M3 Phillips screwdri...

Page 26: ...e proper precautions when wiring the option so that the front covers will easily fit back onto the drive Make sure no cables are pinched between the front covers and the drive when replacing the cover...

Page 27: ...ntation of drives equipped with the SI M3 V option an EDS file can be obtained from U S http www yaskawa com Other areas Contact a Yaskawa representative Communication Speed Max Length of Trunk Line M...

Page 28: ...n Selection after Communications Error Determines drive response when a bUS error is detected during communications with the option 0 Ramp to Stop 1 Coast to Stop 2 Fast Stop 3 Alarm Only 2 Default 1...

Page 29: ...n the AC DC Drive Object Default 0 Min 15 Max 15 F6 58 3D9 Torque Scaling Sets the scaling factor for the Torque Monitor in the CompoNet Object Class 2A hex Note Used in the AC DC Drive Object Default...

Page 30: ...ference of the drive via the master device set b1 01 to 3 or set the Net Reference bit in the assemblies or AC DC object 2 Setting F6 01 or F6 03 to 3 will allow the drive to continue to operate after...

Page 31: ...ator Display Fault Name bUS Option Communication Error After establishing initial communication the connection was lost Only detected when the run command frequency reference is assigned to the option...

Page 32: ...Operator Display Fault Name oFA00 Option Fault Option is not properly connected Cause Possible Solution Non compatible option connected to the drive Use only compatible options Digital Operator Displ...

Page 33: ...et outside the possible setting range Reset the MAC ID in F6 40 to an allowable value Yes Digital Operator Display Fault Name CALL Serial Communication Transmission Error Communication has not yet bee...

Page 34: ...ve for polled operation Table 11 Supported Polled Assemblies PCA and PPA Assembly Number decimal Description Type Bytes Page 20 Basic Speed Control Output 20 0x14 PCA 4 36 21 Default Setting Extended...

Page 35: ...cific Yaskawa Electric YE Assy 151 0x97 PPA 8 152 Standard Status 2 Vendor Specific Yaskawa Electric YE Assy 152 0x98 PPA 8 155 Enhanced Speed Status Dynamic Vendor Specific Yaskawa Electric YE Assy 1...

Page 36: ...1 2 Speed Reference Low Byte 3 Speed Reference High Byte Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 21 CompoNet Extended Speed Control 0 Net Ref Net Ctrl Fault Reset Run Rev Run Fw...

Page 37: ...bytes Output 10 types 4 8 bytes CompoNet Specification Word MIX slave Profile AC Drive Input Power Power is supplied from the drive Connector Type 4 pin open style screw connector Physical Layer Type...

Page 38: ...als appear on the bottom of the back cover Date of Publication Revision Number Section Revised Content July 2012 Back cover Revision Address May 2011 Front cover Revision Format Back cover Revision Ad...

Page 39: ...ww yaskawa com sg YASKAWA ELECTRIC CHINA CO LTD 12F Carlton Bld No 21 HuangHe Road HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELEC...

Reviews: