2 Installation
2.1.1 Linear Servomotor Installation Environment
2-2
2.1
Installation Environment and Applicable Standards
The installation environment and the applicable standards for linear servomotors and
SERVOPACKs are described in this section.
2.1.1
Linear Servomotor Installation Environment
Ambient temperature: 0
C to 40
C
Ambient humidity: 20% to 80% RH or less (with no condensation)
Altitude: 1, 000 m or less
Vibration resistance: The linear servomotor will withstand the
following vibration acceleration in three
directions: vertical, side to side, and front to
back.
Servomotor Model
Vibration Acceleration at
Flange
SGLGW
SGLFW
SGLTW
three directions
49 m/s
2
SGLC
Moving
Coil
three directions
24.5 m/s
2
Magnetic
Way
axis direction
24.5 m/s
2
vertical, hori-
zontal
4.9 m/s
2
Vertical
Vertical
Side to side
axis
direction
horizontal
Fron to back
Impact applied to SGLGW,
SGLFW, and SGLTW models
Impact applied to SGLC model