5.5 Polarity Detection
5-23
5
T
rial Operation (Checking Linear Servomotor Operation)
5.5.4
Related Parameters
Pn481
Changes the sequence input signal allocation for
each signal
Setting Range
Setting Unit
Factory Setting
When enabled
10 to 20000
0.1 Hz
400
Immediately
Pn482
Polarity Detection Speed Loop lntegral Time
Constant
Setting Range
Setting Unit
Factory Setting
When enabled
15 to 51200
0.01 ms
3000
Immediately
Pn485
Polarity Detection Reference Speed
Setting Range
Setting Unit
Factory Setting
When enabled
0 to 100
1 mm/s
20
Immediately
Pn486
Polarity Detection Reference Accel/Decel Time
Setting Range
Setting Unit
Factory Setting
When enabled
0 to 100
1 ms
25
Immediately
Pn487
Polarity Detection Reference Constant Speed
Time
Setting Range
Setting Unit
Factory Setting
When enabled
0 to 300
1 ms
0
Immediately
Pn488
Polarity Detection Reference Waiting Time
Setting Range
Setting Unit
Factory Setting
When enabled
50 to 500
1 ms
100
Immediately
Pn48E
Polarity Detection Range
Setting Range
Setting Unit
Factory Setting
When enabled
1 to 65535
1 mm
10
Immediately
Pn490
Polarity Detection Load Level
Setting Range
Setting Unit
Factory Setting
When enabled
0 to 20000
1%
100
Immediately
Pn495
Polarity Detection Confirmation Force Reference
Setting Range
Setting Unit
Factory Setting
When enabled
0 to 200
1%
100
Immediately
Pn498
Polarity Detection Allowable Error Range
Setting Range
Setting Unit
Factory Setting
When enabled
0 to 30
1
10
Immediately
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force