www.dadehpardazan.ir 88594014-15
6.9 Compatible Adjustment Function
6-71
6
Adjustments
6.9.7
Position Integral
The position integral is the integral function of the position loop. It is used for the electronic cams and elec-
tronic shafts when using the SERVOPACK with YASKAWA MP900/2000 Machine Controllers.
Pn40D
2nd Notch Filter Q Value
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
50 to 1000
0.01
70
Immediately
Tuning
Pn40E
2nd Notch Filter Depth
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 1000
0.001
0
Immediately
Tuning
• Sufficient precautions must be taken when setting the notch filter frequencies. Do not
set the notch filter frequencies (Pn409 or Pn40C) that is close to the speed loop’s
response frequency. Set the frequencies at least four times higher than the speed
loop’s response frequency. Setting the notch filter frequency too close to the response
frequency may cause vibration and damage the machine.
• Change the notch filter frequencies (Pn409 or Pn40C) only when the servomotor is
stopped. Vibration may occur if the notch filter frequency is changed when the servo-
motor is moving.
(cont’d)
Speed
Position
Force
Speed
Position
Force
Pn11F
Position Integral Time Constant
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 50000
0.1 ms
0
Immediately
Tuning
Position
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...