4.3 Wiring the Power Supply to the SERVOPACK
4.3.5 Wiring Regenerative Resistors
4-18
4.3.5
Wiring Regenerative Resistors
This section describes how to connect External Regenerative Resistors.
Refer to the catalog to select External Regenerative Resistors.
Connecting Regenerative Resistors
1.
Remove the wire connected between the B2 and B3 terminals.
2.
Connect the External Regenerative Resistor between the B1 and B2 terminals on the
SERVOPACK.
3.
Set Pn600 (Regenerative Resistor Capacity) and Pn603 (Regenerative Resistor Resistance).
Refer to the following section for details on the settings.
6.17 Setting the Regenerative Resistor Capacity
4.3.6
Wiring Reactors for Harmonic Suppression
You can connect a reactor for harmonic suppression to the SERVOPACK when power supply har-
monic suppression is required. Connection terminals 1 and 2 for a DC Reactor are connected
when the SERVOPACK is shipped. Remove the lead wire and connect a DC Reactor as shown in
the following diagram.
WARNING
Be sure to wire Regenerative Resistors correctly. Do not connect B1/
⊕
and B2.
Doing so may result in fire or damage to the Regenerative Resistor or SERVOPACK.
Enlarged View
1
2
SERVOPACK
-
-
DC Reactor