4.3 Wiring the Power Supply to the SERVOPACK
4.3.2 Connector Wiring Procedure
4-13
4
W
iring and Connecting SER
VOP
ACKs
4.3.2
Connector Wiring Procedure
•
Required Items: Phillips or flat-blade screwdriver
1.
Prepare the connector that was provided with the SERVOPACK.
2.
Remove the sheath from the wire to connect.
3.
Open the wire insertion hole on the terminal connector with the screwdriver.
4.
Make all other connections in the same way.
5.
When you have completed wiring, attach the connector to the SERVOPACK.
6.
Press the connector all the way to the back and lock it with the lock lever.
SERVOPACK model
SGD7S-
Terminal Symbols
Screwdriver
Type
Screwdriver End
Dimensions
Thickness × Width
[mm]
Wire Stripping
Length [mm]
1R9D, 3R5D, 5R4D,
8R4D, 120D, 170D
L1, L2, L3, B1, B2, B3, -1, -2
Flat-blade
0.6
×
3.5
7
U, V, W, PE
Phillips or
flat-blade
7
24 V, 0 V
Flat-blade
10
210D, 260D, 280D,
370D
L1, L2, L3, B1, B2, B3, -1, -2
Phillips or
flat-blade
1.0
×
5.5
12
U, V, W, PE
Phillips or
flat-blade
12
24 V, 0 V
Flat-blade
10
Main Circuit Terminals and Motor Terminals
Control Power Supply Terminals
Insert the conductor of the wire into the wire inser-
tion hole, insert the screwdriver into the screwdriver
insertion hole, and tighten the screw.
Press the lever with a screwdriver or your fingertip
and insert the conductor of the wire into the wire
insertion hole.
After you insert conductor, release the screwdriver
or your fingertip.
Wire
Wire
Lock lever