6.3 Trial Operation for Servomotor without Load
6.3.2 Operating Procedure
6
T
rial Operation
6-7
•
Linear Servomotors
6.3.2
Operating Procedure
Use the following procedure to jog the motor.
1.
Click the
Servo Drive
Button in the workspace of the Main Window of the Sig-
maWin+.
2.
Select
JOG
in the Menu Dialog Box.
The Jog Operation Dialog Box will be displayed.
3.
Read the warnings and then click the
OK
Button.
4.
Check the jogging speed and then click the
Servo ON
Button.
The display in the
Operation
Area will change to
Servo ON
.
Pn383
Jogging Speed
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 mm/s
50
Immediately
Setup
Pn305
Soft Start Acceleration Time
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 ms
0
Immediately
Setup
Pn306
Soft Start Deceleration Time
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 ms
0
Immediately
Setup
S
peed
Po
s
ition
Force
S
peed
S
peed
To change the speed, click the
Edit
Button and enter the new speed.
Information