8 Conventional Formats
YASKAWA ELECTRIC
SIEP C730600 23A V1000 Option PROFIBUS-DP Technical Manual
27
0080H
Current fault (U2-01)
0081H
Previous fault (U2-02)
0082H
Frequency reference at previous fault (U2-03)
0083H
Output reference at previous fault (U2-04)
0084H
Output current at previous fault (U2-05)
0085H
Motor speed at previous fault (U2-06)
0086H
Output voltage at previous fault (U2-07)
0087H
DC bus voltage at previous fault (U2-08)
0088H
Output power at previous fault (U2-09)
0089H
Torque reference at previous fault (U2-10)
008AH
Input terminal status at previous fault (U2-11)
008BH
Output terminal status at previous fault (U2-12)
008CH
Drive operation status at previous fault (U2-13)
008DH
Cumulative operation time at previous fault (U2-14)
008EH
Reserved
0090H
Most recent fault (U3-01)
0091H
2nd most recent fault (U3-02)
0092H
3rd most recent fault (U3-03)
0093H
4th most recent fault (U3-04)
0094H
Cumulative operation time at most recent fault (U3-11)
0095H
Cumulative operation time at 2nd most recent fault (U3-12)
0096H
Cumulative operation time at 3rd most recent fault (U3-13)
0097H
Cumulative operation time at 4th most recent fault (U3-14)
0098H
Cumulative operation time
Shows “X” digit of the operation time, which is
displayed as “XY”
For the “Y” digit, see 1099H
0099H
Cumulative operation time
Shows “Y” digit of the operation time, which is
displayed as “XY”
For the “X” digit, see 1098H
009AH
Cooling fan operation time, upper digits
Shows “X” digit of the operation time, which is
displayed as “XY”
For the “Y” digit, see 1099H
009BH
Cooling fan operation time, lower digits
Shows “Y” digit of the operation time, which is
displayed as “XY”
For the “X” digit, see 1098H
00ABH
Drive rated current
The unit is 0.01 A for drives set up to 11 kW in
Heavy Duty or Normal Duty and 0.1 A for drives
set up for 15 kW and above.
00ACH
Motor speed (U1-05)
Units: min
-1
*1
00ADH
Motor speed (U1-05)
Units: 0.01%
00AEH
Iac monitor with filter
8192/100%
00B0H
Option A code
The option code for the communication card is
the ASCII code for the first and third digits of
the product model number. If the model number
is SIP3, then the first and third digits are "S" and
"P", for an ASCII code of 5343H.
00B2H
Reserved
00B3H
Reserved
00B5H
Output frequency after soft starter (U1-16)
Units: min
-1
*1
00B6H
Output frequency after soft starter (U1-16)
Units: 0.01%
00B7H
Frequency reference monitor
Units: min
-1
*1
00B8H
Frequency reference monitor
Units: 0.01%
00B9H
Reserved
00BAH
Reserved
00BFH
Operation error number (oPE
)
Register
Command Name
Comments
Bit
*1. It is necessary to set the pole number (E2-04, E4-04, or E5-04) in the drive.
*2. See
Fault Contents on page 30
for information on fault contents.
*3. See
Alarm Contents on page 32
for information on alarm contents.