A.2 Parameter Table
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
301
Para
me
te
r Lis
t
A
b2-08
Magnetic Flux
Compensation
Capacity
Sets the magnetic flux compensation as a
percentage of the no-load current value
(E2-03).
0 to
1000
0%
−
A
−
190
b2-12
Short Circuit Brake
Time at Start
Sets the time for Short-Circuit brake operation
at start. Disabled when set to 0.00.
0.00 to
25.50
0.00
s
− −
A 1BA
b2-13
Short Circuit Brake
Time at Stop
Sets the Short-Circuit brake operation time at
stop. Used to stop a motor rotating due to
inertia. Disabled when set to 0.00 seconds.
0.00 to
25.50
0.50
s
− −
A 1BB
b3: Speed Search
Use B3 parameters to configure Speed Search function operation.
b3-01
Speed Search
Selection
Enables/disables the Speed Search function at
start.
0: Disabled - Speed Search is not automatically
performed at start.
1: Enabled - Speed Search is automatically
performed at start.
0 to 1
0
A A A
191
b3-02
Speed Search
Deactivation Current
Sets the current level at which the speed is
assumed to be detected and Speed Search is
ended. Set as a percentage of the drive rated
current.
0 to 200
120
A A
−
192
b3-03
Speed Search
Deceleration Time
Sets the time constant used to reduce the output
frequency during Speed Search. Related to a
change from max. output frequency to 0.
0.1 to
10.0
2.0 s A A
−
193
b3-05
Speed Search Delay
Time
Delays the Speed Search operation after a
momentary power loss to allow time for an
external output contactor to close.
0.0 to
100
0.2 s A A A
195
b3-06
Output Current 1
during Speed Search
Sets the current injected to the motor at the
beginning of Estimation type Speed Search. Set
as a factor of the motor rated current.
0.0 to
2.0
A A
−
196
b3-10
Speed Search
Detection
Compensation Gain
Sets the gain which is applied to the speed
detected by Speed Estimation Speed Search
before the motor is reaccelerated. Increase this
setting if OV occurs when performing Speed
Search.
1.00 to
1.20
1.05 A A
−
19A
b3-14
Bi-Directional Speed
Search Selection
Selects if Speed Search detects the motor
rotation direction during Speed Search.
0: Disabled–Frequency reference direction used
1: Enabled–Detected direction used
0,1
0
A A
−
19E
b3-17
Speed Search Restart
Current Level
Sets the Speed Search restart current level as a
percentage of the drive rated current.
0 to 200
150
%
A A
−
1F0
No.
Name
Description
Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
O
LV
P
M