2.10 Communications with a JTEKT PLC (TOYOPUC Protocol)
Message Functions
2-313
Ethernet Communications
Function Code (PARAM12)
This parameter gives the function code that was received.
When the MP3000 receives the file memory data sent from the 2PORT-EFR, the data is converted to the
format specified in MEMOBUS command 31 hex and sent to the CPU Module.
Reserved for System (PARAM13)
This parameter is used by the system.
Data Address (PARAM14 and PARAM15)
These parameters are not used for the TOYOPUC protocol.
Register Type (PARAM16)
This parameter is not used for the TOYOPUC protocol.
Data Size (PARAM17)
This parameter gives the data size as the number of words to write as requested by the remote station.
Remote CPU Module Number (PARAM18)
This parameter is not used for the TOYOPUC protocol.
Reserved for System (PARAM19)
This parameter is used by the system.
File Memory Frame Type
MEMOBUS Function
Code
Function
Code
Meaning
60 hex: Command
E0 hex: Response
Sends file memory data.
31 hex
Writes to a fixed buffer in
units of one word.
Do not change the value of PARAM13 from a user program or by any other means.
Do not change the value of PARAM19 from a user program or by any other means.
Note
Note