YASKAWA MP2200 Manual Download Page 5

5  Notes for Safe Operation

E-3

5  Notes for Safe Operation

Read this manual thoroughly before checking products on delivery, storage and transportation,  
installation, wiring, maintenance and inspection, and disposal of the MP2200/MP23

†††

/

MP2400 Machine Controller.

•  Before starting operation with a machine connected, make sure that an emergency stop can 

be applied at any time. 

Failure to observe this warning may result in injury.

•  Never touch the inside of the unit. 

Failure to observe this warning may result in electric shock.

•  Do not remove the front cover while the power is ON.

Failure to observe this warning may result in electric shock.

•  Follow the procedures and instructions for trial operation precisely as noted in the Machine 

Controller MP2200 User’s Manual (Manual No.: SIEP C880700 14), the Machine Controller 
MP2300 Basic Module User’s Manual (Manual No.: SIEP C880700 03), the Machine Con-
troller MP2300S Basic Module User’s Manual (Manual No.: SIEP C880732 00), the Machine 
Controller MP2310 Basic Module User’s Manual (Manual No.: SIEP C880732 01), and the 
Machine Controller MP2400 User’s Manual (Manual No.: SIEP C880742 00).

Malfunctions that occur after the servomotor is connected to the equipment not only damage the 
equipment, but may also cause an accident resulting in death or injury.

•  Do not damage, press, exert excessive force or place heavy objects on the cables.  

Failure to observe this warning may result in electric shock, stopping operation of the product, or 
burning.

•  Do not modify the product.

Failure to observe this warning may result in injury or damage to the product.

•  Do not come close to the machine immediately after resetting momentary power loss to 

avoid an unexpected restart.  Take appropriate measures to ensure safety against an unex-
pected restart.

Failure to observe this warning may result in injury.

•  Installation, disassembly, or repair must be performed only by authorized personnel.

Failure to observe this warning may result in electric shock or injury.

WARNING

Summary of Contents for MP2200

Page 1: ...E JEPMC AN29 E JEPMC MTD2310 E JEPMC BU22 E JAPMC CP22 E JAPMC MC23 E JEPMC REP2000 E JAPMC EX22 E JAPMC PL23 E JAPMC CP2700 E JAPMC AN23 E JAPMC DO23 E JEPMC MP2300S E JEPMC MP2400 E JAMSC IO29 E JEP...

Page 2: ...liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is con stantly striving to improve its high quality products the information contained in this...

Page 3: ...fic modification and manual improvement When this manual is revised the manual code is updated and the new manual is published as a next edition The edition number appears on the front and back covers...

Page 4: ...us injury Indicates precautions that if not heeded could result in relatively serious or minor injury damage to the product or faulty operation In some situations the precautions indicated could have...

Page 5: ...roller MP2300S Basic Module User s Manual Manual No SIEP C880732 00 the Machine Controller MP2310 Basic Module User s Manual Manual No SIEP C880732 01 and the Machine Controller MP2400 User s Manual M...

Page 6: ...to a core temperature of 56 C for 30 minutes or more If the electronic products which include stand alone products and products installed in machines are packed with fumigated wooden materials the el...

Page 7: ...it power supply configure the circuit that turns it ON If the Machine Controller main unit power supply is turned ON after an external power supply such as a 24 V power supply for the I O is turned ON...

Page 8: ...Failure to observe this caution may result in electric shock or injury When replacing the MP2200 MP23 MP2400 resume operation only after transferring the previous MP2200 MP23 MP2400 programs and para...

Page 9: ...communication MP2400 Main Unit Basic Module MP2400 JEPMC MP2400 E Power supply Mounting base CPU MECHATROLINK I MECHATROLINK II Ethernet communication Option Module Motion Module SVA 01 JAPMC MC2300...

Page 10: ...E 8 inputs 8 outputs sink mode output IO2950 E JAMSC IO2950 E 8 relay outputs PL2900 JEPMC PL2900 E Reversible counter input 2 channels PL2910 JEPMC PL2910 E Pulse output 2 channels AN2900 JEPMC AN29...

Page 11: ...the modules are located on the top of the board A module do not have a nameplate MP2300 YASKAWA RDY ALM TX RUN ERR BAT BATTERY SW1 OFF ON M 4 10 CPU I O POWER DC24V DC 0V STOP SUP INIT CNFG MON TEST O...

Page 12: ...anel install cooling fans and provide sufficient space around each MP2200 MP23 MP2400 to allow cooling by fan and natural convection When installed near a heating unit Suppress radiation heat from the...

Page 13: ...ply for the I O is turned ON the output from the option output module or the option output unit may be momentarily turned ON Before turning ON the Machine Controller main unit power supply configure t...

Page 14: ...N output interlock output of the MP2000 module Power ON Sequence Circuit Configuration Example MP2000 module power supply CPU RUN signal Output device power supply OFF ON OFF OFF ON ON DC power supply...

Page 15: ...invalid Power ON Sequence Circuit Configuration Example MP2000 module power supply OFF OFF CPU RUN output Another module startup Another module output Application stop Output valid ON ON Interlock ou...

Page 16: ...ATROLINK II 64 points I O module sink mode output JEPMC IO2330 E MECHATROLINK II 64 points I O module source mode output JEPMC AN2910 E MECHATROLINK II analog output module JAMSC IO2910 E 16 outputs o...

Page 17: ...C Ambient Storage Temperature 25 to 85 C Ambient Operating Humidity 30 to 95 RH with no condensation Ambient Storage Humidity 5 to 95 RH with no condensation Pollution Level Pollution level 1 conformi...

Page 18: ...MC2310 E SVB 01 Back cover Revision Address October 2011 0 Inside of back cover Addition Precautions for Korean Radio Waves Act June 2011 0 TOBP C880700 02I 14 1 available on the Web April 2011 1 Chap...

Page 19: ...hapters Addition Model JAPMC EX22 April 2004 All chapters Slightly revised September 2003 All chapters Addition Model JEPMC BU22 JAPMC MC23 June 2003 All chapters Addition Model JEPMC PL29 JEPMC AN29...

Page 20: ...gHe Road HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECTRIC CHINA CO LTD BEIJING OFFICE Room 1011 Tower W3 Oriental Plaza No 1 Ea...

Page 21: ...Precautions for Korean Radio Waves Act A A...

Reviews: