49
Be sure to connect the connector of the new battery before disconnecting the old battery.
If the current battery is disconnected before connecting the new battery, the robot will lose
the home position data and the calibration must be executed again.
Except with announcement of the warning " Battery condition critically".
5. Cut off the wire tie banding the cables of used lithium battery.
6. Cut off the wire tie banding the lithium battery and remove the lithium battery
Battery unit (lithium battery)
1. Mount the new lithium battery to the battery board.
2. Please follow disassembly step (4) to fasten the wires of the lithium battery and the
connector of the battery board.
3. Install the upper arm cover.
4. Turn ON the Controller.
5. Check if the robot moves to points (poses) correctly. To do so, select 2 points (poses) or
more from the registered points (poses) and move the robot to the points (poses).
X60B
X60A
Cable tie
Lithium battery
Battery Board
Summary of Contents for MOTOMAN MYS450L
Page 26: ...26 E1101000117GB01 MYS450L 5 3 Dimensions 4 5 12 1 200 6 7 8 9 10 3 11 Dimensions mm...
Page 40: ...40 E1101000117GB01 MYS450L 8 Electrical Equipment Specification 8 1 Signal cable BASE ARM2...
Page 41: ...MYS450L E1101000117GB01 41 8 2 Power cable BASE ARM2...
Page 60: ...60 E1101000117GB01 MYS450L...
Page 61: ...MYS450L E1101000117GB01 61...