9.3.5 Grease Replenishment/Exchange for T-Axis Speed Reducer
Fig. 9-7: T-Axis Speed Reducer Diagram
9.3.5.1 Grease Replenishment
(Refer to
Fig. 9-7 “T-Axis Speed Reducer Diagram”
1. Remove the hexagon socket head plugs from the grease inlet and
grease exhaust port.
2. Install a grease zerk A-PT1/8 to the grease inlet.
(The grease zerk is delivered with the manipulator.)
3. Inject grease through the grease inlet using a grease gun
– Grease type:
Molywhite RE No.00
– Amount of grease:
180 cc
(360 cc for 1st supply)
– Air supply pressure of grease pump: 0.3 MPa or less
– Grease injection rate:
8 g/s or less
4. Move the T-axis for a few minutes to discharge excess grease.
5. Wipe the discharged grease with a cloth, and reinstall the plug. Before
installing the plug, apply Three Bond 1206C on the thread part of the
plug. Then tighten the plug with a tightening torque of 4.9 N•m
(0.5 kgf•m).
Grease inlet
Hexagon socket head plug
T-axis speed reducer
Grease exhaust port
Hexagon socket head plug
NOTE
• If grease is injected with the plug on, grease will leak
inside the motor and may cause a damage. Make sure to
remove the plug before the grease injection.
• Do not install a joint, a hose, etc. to the grease exhaust
port. Failure to observe this instruction may result in
damage to the motor due to coming off of an oil seal.