5-7
157569-1CD
HW0485652
MPL100
5 Basic Specifications
5.5 Alterable Operating Range
5.5.3 Adjustment of the Soft Limit of the S-Axis Pulse
To limit the operating range of the S-axis, refer to "DX100 Concurrent I/O
(manual No. RE-CKI-A453)" and change the following parameters with the
programming pendant.
Pulse limit (positive (+) direction of the S-axis): SICxG400
Pulse limit (negative (-) direction of the S-axis): SICxG408
MPL100
Degree
Number of Pulse
0
0
15
1)
1 Refer to
section 5.5 “Alterable Operating Range”
.
29089
30
58179
45
87268
60
116357
75
145446
90
174536
105
203625
120
232714
135
261804
150
290893
165
319982
180
349071
NOTE
Adjust both of the pulse limit and the angle of the S-axis
mechanical stopper when modifying the range of motion of
the manipulator.
35 of 106