Figure 3.10 Configuration of Main Circuit Terminal Block (Three-Phase, With a Built-in EMC Filter)
◆
Main Circuit Terminal Functions
Table 3.1 Main Circuit Terminal Functions
Terminal
Name
Function
Model
4009 - 4045
R/L1
Main circuit power supply input
To connect a commercial power supply.
S/L2
T/L3
L/L1
-
N/L2
U/T1
Drive output
To connect a motor.
V/T2
W/T3
+1
DC reactor connection
Remove the jumper between ter1 and +2 to connect a DC reactor.
+2
B1
Braking resistor connection
To connect a braking resistor or braking resistor unit.
B2
Ground Wiring
To ground the drive.
•
400 V: C class grounding (ground to 10 Ω or less)
◆
Wire Selection
Select the correct wires for main circuit wiring.
Refer to
Main Circuit Wire Gauges and Tightening Torques on page 114
for wire gauges and tightening torques as
specified by European standards.
◆
Main Circuit Terminal and Motor Wiring
This section outlines the various steps, precautions, and checkpoints for wiring the main circuit terminals and
motor terminals.
Summary of Contents for LA500
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...