5.6 F: Option Settings
■ F1-52: Communication Speed of Serial Encoder Selection
Note: Available in drive software PRG: 7016 and later.
Selects the speed for serial communication between a PG-F3 option card and serial encoder.
No.
Parameter Name
Setting Range
Default
F1-52
Communication Speed o f Serial Encoder Selection
0 to 3
0
0: 1M bps / 9600 bps (EnDat 2.2/22 / Hiperface)
1: 500k bps / 19200 bps (EnDat 2.2/22 / Hiperface)
2: 1M bps / 38400 bps (EnDat 2.2/22 / Hiperface)
3: 1M bps / 38400 bps (EnDat 2.2/22 / Hiperface)
■ F1-63: PG-E3 R Track Selection
Enables or disables the R phase when a PG-E3 option card is used.
No.
Parameter Name
Setting Range
Default
F1-63
PG-E3 R Track Selection
0, 1
0
0: Disabled
The R track is not used. The rotor magnet position is calculated from the C and D track signal only.
1: Enabled
The R track signals are used to determine the rotor magnet position.
♦ F3: Digital Input Card Settings
These parameters set up the drive for operation with the option card DI-A3. Refer to the instruction manual packaged
with the option card for specific details on installation, wiring, input signal level selection, and parameter setup.
■ F3-01: DI-A3 Option Card Input Selection
Determines the type o f input for digital option card DI-A3 when o1-03 is set to 0 or 1.
No.
Parameter Name
Setting Range
Default
F3-01
DI-A 3 Option Card Input Selection
0 to 7
0
Setting 0: BCD, 1% units
Setting 1: BCD, 0.1% units
Setting 2: BCD, 0.01% units
Setting 3: BCD, 1 Hz units
Setting 4: BCD, 0.1 Hz units
Setting 5: BCD, 0.01 Hz units
Setting 6: BCD, special setting (5 digit input), 0.02 Hz units
Setting 7: Binary
The unit and the setting range are determined by F3-03.
F3-03 = 0: 255/100% (-255 to +255)
F3-03 = 1: 4095/100% (-4095 to +4095)
F3-03 = 2: 30000/100% (-33000 to +33000)
Note: BCD input w hen o1-03 = 2 or 3. U nits are determined by o1-03.