9 Replacement Instructions for Smart Controller Drives
76
YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
Figure 9.3 Wiring Between Controller and Drive Terminals
The following table summarizes the terminal connections in the old and new configurations.
Table 9.2 Terminal Connections
Controller SMCCFC Terminal Vacon Drive Terminal
YASKAWA L1000A Terminal
Brake Relay
Function
-
M2
A1
Connection for Brake Relay
1
26
-
4
3
25
-
3
5
6
SP, M1
-
-
6
8
S1
-
Direction / Run
7
20
M4
-
-
8
14
S3
-
Nominal / Fast Speed
9
15
S6
-
Inspection / Leveling
10
16
S7
-
Landing Zone
11
17
SC, SN, M3
A2 (Relay Coil)
-
Connection for Brake Relay
1
22
M5
-
Safety Circuit
3
23
M6
-
◆
Start Up
After wiring, power on the drive and follow these steps
1.
Enter the programming mode of the L1000A.
2.
Set parameter
d1-18 = 4 [Smart Replacement]
.
This operation sets I/Os to operate with the Smart controller.
3.
Set drive parameters.
With this step, you enter motor data to the drive.
Yaskawa L1000A Drive
S1
S3
S6
S7
M4
M3
SC
Terminal Numbering
SN
M2
S
M1
M5
M6
8
14
15
16
20
17
25
26
22
23
6
Safety Circuit
1
3
Brake Signal
24 V
3
1
5
6
8
9
10
7
Up/
Down
High
Speed
Slow
Speed
Landing
Zone
Slow
Down
0 V
Terminal Numbering XFCL Terminal
Controller (SMCCFC Board)/Drive Terminals
11
Terminal Numbering Old Drive
3
4
A1
A2
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...