9 Replacement Instructions for Smart Controller Drives
YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
75
9
Replacement Instructions for Smart Controller Drives
The following describes how to replace the drive in Schindler Smart controllers with a YASKAWA L1000A AC
drives for Lift. This solution has been developed to replace drives used in Smart MRL 001 / 002 controllers.
◆
Requirements
The L1000A can almost directly replace existing drives. The only additional component needed is an external
relay to control the brake.
YASKAWA recommends a relay from the 46.52 series made by Finder. When other relays are used it should be
selected so that the excitation current of the coil does not exceed the specifications of the output M2 on the
L1000A drive. Generally the relay should be selected so that the excitation current is as low as possible.
Figure 9.1 Finder Relay
Figure 9.2 Circuit of the Relay
Table 9.1 DC Coil Data
Nominal Voltage
Coil Code
Operating Range
Resistance
Rated Coild
Consumption
U
N
[V]
U
min
[V]
U
max
[V]
R [
Ω
]
I at U
N
[mA]
24
9.024
17.5
26.4
1,200
20
◆
Wiring of the L1000A AC Drive for Lift
The following figure shows the wiring between the controller (connector XFCL) and the drive terminals.
EN
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...