2 Brake Monitoring (Unintended Car Movement)
YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
13
Figure 2.6 Fault during Run
◆
Function Test
Selecting the Brake Feedback function on only one or more than two digital inputs, or mixing the functions
(selecting 79h & 5Bh) triggers an
oPE03
fault if the Brake Response Monitor function is enabled
[S6-17 = 1]
.
In case of an
oPE03
fault, check if two inputs have been programmed as Brake Feedback and if they are both
programmed to the same function.
For example:
•
H1-07 = 79h
&
H1-08 = 79h
or
•
H1-07 = 5Bh
&
H1-08 = 5Bh
If the Brake Response Monitor function is enabled
[S6-17 = 1]
and the
SE4
fault appears, verify the Brake
Monitor Function before you can reset the
SE4
fault.
■
Function Test NPN Logic
The following steps have to be performed for the functional test after commissioning when using NPN logic:
1. Disconnect the signal Brake Feedback 1 (e.g. input S7).
2. Execute test travel.
3. During start an
SE4
fault should be triggered and the drive should immediately stop.
4. The drive should be blocked and no further travel should be possible even after power cycle.
5. Reconnect the signal Brake Feedback 1.
6. Execute test travel.
7. The drive should be blocked and no further travel should be possible even after power cycle.
8. Set
S6-18 = 1
to unlock the drive.
EN
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...