PP.P5G5.03.Troubleshoot
Page 32
Rev. 06/11/2003
The deviation of the speed reference and speed
feedback has exceeded the regulation level.
A minor fault contact output can be programmed by
using the multi-function outputs.
DEV
Speed Deviation
N/A
Possible Cause(s):
The load has changed considerably.
Corrective Action:
Check the load on the motor, verify the program settings (F1-10 PG
Deviate Level, F1-11 PG Deviate Time. F1-04 PG Deviation Select.
Possible Cause(s):
Connection is broken, master has stopped communicating.
Corrective Action:
Check all connections, verify all user side software configurations.
CE
Memobus Com Err
Transmission error. Control data was not received
normally when the power supply is turned on.
Response may be selected.
ce
Fault Codes
Minor Fault
- Operation continues and the digital operator indication blinks
The fault relay does not activate.
505
506
515
√
505
506
√
515
√