116
YASKAWA
TOEPC71061737D GA800 DRIVE INSTALLATION & PRIMARY OPERATION
Model
Terminal
Recomm. Gauge
mm
2
Applicable Gauge
(IP20 Applicable Gauge
)
mm
2
Wire Stripping
Length
mm
Terminal Screw
Size and Shape
Tightening Torque
N
∙
m (lbf
∙
in)
2360
R/L1, S/L2, T/L3
120 × 2P
70 - 150 × 2P
(150 × 2P)
-
M12
35
(310)
U/T1, V/T2, W/T3
120 × 2P
70 - 150 × 2P
(150 × 2P)
-
M12
35
(310)
-, +1
120 × 2P
95 - 185 × 2P
(185 × 2P)
-
M12
35
(310)
+3
70 × 2P
50 - 95 × 2P
(-)
-
M12
35
(310)
120
120 - 240
(-)
-
M12
32 - 40
(283 - 354)
2415
R/L1, S/L2, T/L3
120 × 2P
70 - 150 × 2P
(150 × 2P)
-
M12
35
(310)
U/T1, V/T2, W/T3
120 × 2P
70 - 150 × 2P
(150 × 2P)
-
M12
35
(310)
-, +1
120 × 2P
95 - 185 × 2P
(185 × 2P)
-
M12
35
(310)
+3
70 × 2P
50 - 95 × 2P
(-)
-
M12
35
(310)
120
120 - 240
(-)
-
M12
32 - 40
(283 - 354)
*1
For IP20 protection, use wires that are in the range of applicable gauges.
*2
Remove insulation from the ends of wires to expose the length of wire shown.
*3
Terminals - and +1 have two screws. The Recommended Gauge is the wire gauge for one terminal.
*4
A junction terminal is necessary to connect a braking unit (CDBR-series) to terminals - and +3.
Three-Phase 400 V Class
Model
Terminal
Recomm. Gauge
mm
2
Applicable Gauge
(IP20 Applicable Gauge
)
mm
2
Wire Stripping
Length
mm
Terminal Screw
Size and Shape
Tightening Torque
N
∙
m (lbf
∙
in)
4002
R/L1, S/L2, T/L3
2.5
2.5 - 10
(2.5 - 10)
10
M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3
2.5
2.5 - 10
(2.5 - 10)
10
M4
1.5 - 1.7
(13.5 - 15)
-, +1, +2
2.5
2.5 - 16
(2.5 - 16)
18
M5
2.3 - 2.5
(19.8 - 22)
B1, B2
2.5
2.5 - 4
(2.5 - 4)
10
M4
1.5 - 1.7
(13.5 - 15)
2.5
2.5 - 10
(-)
-
M4
1.2 - 1.5
(10.6 - 13.3)
4004
R/L1, S/L2, T/L3
2.5
2.5 - 10
(2.5 - 10)
10
M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3
2.5
2.5 - 10
(2.5 - 10)
10
M4
1.5 - 1.7
(13.5 - 15)
-, +1, +2
2.5
2.5 - 16
(2.5 - 16)
18
M5
2.3 - 2.5
(19.8 - 22)
B1, B2
2.5
2.5 - 4
(2.5 - 4)
10
M4
1.5 - 1.7
(13.5 - 15)
2.5
2.5 - 10
(-)
-
M4
1.2 - 1.5
(10.6 - 13.3)