No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T2-13
(0755)
Back-EMF Units
Selection
Sets the units that the drive uses to set the induced voltage constant.
0 : mV/(rev/min)
1 : mV/(rad/sec)
0
(0, 1)
T2-14
(0737)
Back-EMF Voltage
Constant (Ke)
Sets the motor induced voltage constant (Ke).
Determined by T2-13
(0.0 - 2000.0)
T2-15
(0756)
Pull-In Current Level
Sets the level of the pull-in current as a percentage of
E5-03 [PM Motor Rated Current
(FLA)]
. Usually it is not necessary to change this setting.
30%
(0 - 120%)
◆
T3: ASR and Inertia Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T3-00
(1198)
Control Loop Tuning
Selection
Sets the type of Control Auto-Tuning.
2 : Deceleration Rate Tuning
3 : KEB Tuning
2
(2, 3)
◆
T4: EZ Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T4-01
(3130)
EZ Tuning Mode
Selection
Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
0
(0, 1)
T4-02
(3131)
Motor Type Selection
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
0
(0, 1, 2)
T4-04
(3133)
Motor Rated Revolutions
Sets rated rotation speed (min
-1
) of the motor.
-
((40 Hz to 120 Hz) × 60 ×
2/E9-08)
T4-05
(3134)
Motor Rated Frequency
Sets the rated frequency (Hz) of the motor.
Determined by E9-01 and
o2-04
(40.0 - 120.0 Hz)
T4-06
(3135)
Motor Rated Voltage
Sets the rated voltage (V) of the motor.
200 V Class: 230.0 V, 400
V: 460.0 V
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
T4-07
(3136)
Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
T4-08
(3137)
Motor Rated Capacity
Sets the motor rated power in the units set in
o1-58 [Motor Power Unit Selection]
.
Determined by E9-10
(0.10 - 650.00 HP)
T4-09
(3138)
Number of Poles
Sets the number of motor poles.
Determined by E9-01
(2 - 48)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for GA500 series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...