82
YASKAWA
TOEPYAIGA5002A GA500 Programming
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
n8-78
(05F4)
RUN
Expert
Medium Load Id Current
Sets the level of the pull-in current as a percentage, where
E5-03 [PM Motor Rated
Current (FLA)] = 100%
.
0%
(0 - 255%)
n8-79
(05FE)
Pull-in Current @
Deceleration
Sets the pull-in current that can flow during deceleration as a percentage of the
E5-03 [PM
Motor Rated Current (FLA)]
.
Note:
When
n8-79 = 0
, the drive will use the value set in
n8-51 [Pull-in Current @
Acceleration]
.
50%
(0 - 200%)
n8-84
(02D3)
Expert
Polarity Detection
Current
Sets the current that the drive uses to estimate the initial motor magnetic pole as a
percentage where
E5-03 [PM Motor Rated Current (FLA)] = 100%
.
100%
(0 - 150%)
n8-87
(02BC)
Output Voltage Limit
Method
Sets the method of output voltage limit. If there is vibration in the constant output range,
set Feedforward Method. Usually it is not necessary to change this setting.
0 : Feedback Method
1 : Feedforward Method
0
(0, 1)
n8-88
(02BD)
Vout Limit Switching
Level
Sets the current level at which output voltage limit sequence selection occurs as a
percentage where the motor rated current is 100%. Normally there is no need to change
this setting.
Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the motor
rated current.
•
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
•
A1-02 = 8[EZOLV]: E9-06 [PM Motor Rated Current (FLA)]
400%
(0 - 400%)
n8-89
(02BE)
Vout Limit Switching
Hysteresis
Sets the hysteresis width of the current level at which output voltage limit sequence
selection occurs as a percentage where the motor rated current is 100%. Normally there is
no need to change this setting.
Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the motor
rated current.
•
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
•
A1-02 = 8[EZOLV]: E9-06 [PM Motor Rated Current (FLA)]
3%
(0 - 400%)
n8-90
(02BF)
Vout Limit Switching
Speed
Sets the speed level at which output voltage limit sequence selection occurs as a
percentage where the maximum output frequency is 100%. Usually it is not necessary to
change this setting.
Note:
Parameter
A1-02 [Control Method Selection]
selects which parameter is the maximum
output frequency.
•
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E1-04 [Maximum Output Frequency]
•
A1-02 = 8: E9-02 [Motor Max Revolutions]
200%
(0 - 200%)
n8-91
(02F7)
Id Limit at Voltage
Saturation
Sets the limit value of feedback output voltage limit Id operation. Enabled when
n8-87 = 0
[Output Voltage Control Selection = Speed Feedback Form]
. Usually it is not necessary to
change this setting.
-50%
(-200 - 0%)
n8-94
(012D)
Expert
Flux Position Estimation
Method
Sets the criteria that the drive uses to find changes in speed or load. Usually it is not
necessary to change this setting.
0 : Softstarter
1 : Speed Feedback
1
(0, 1)
n8-95
(012E)
Expert
Flux Position Est Filter
Time
Sets the time constant of the filter used for the recognition criteria value for speed and load
changes. Usually it is not necessary to change this setting.
30 ms
(0 - 100 ms)
◆
nA: PM Motor Control Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
nA-01
(3129)
Expert
Observer Calc Gain 3
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
30.0
(0.0 - 1000.0)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for GA500 series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...