u
F1: PG Speed Control Card Settings
Yaskawa offers a PG-X3 and PG-B3 motor encoder PG option card. Use the CN5-C port when using only one PG option
card and use the CN5-C and CN5-B ports when using two PG option cards. When programming one of the contact input
to act as a switch between two motors (H1-
= 16), use the card connected to port CN5-C for motor 1 and use the card
connected to CN5-B for motor 2.
lists the parameters that must be set for each option card port.
Table 2.19 Option Card Ports and Corresponding Parameters
n
F1-01, F1-31: PG 1 and PG 2 Pulses Per Revolution
Sets the number encoder number of pulses per revolution.
n
F1-02, F1-14: PG Open (PGo) Circuit Operation Selection, Detection Time
A PGo fault is triggered if the drive receives no pulse signal for longer than the time set in F1-14. The stopping method
when PGo occurs should be set to parameter F1-02.
Parameter F1-02 Settings:
Setting 0: Ramp to stop (uses the deceleration time set to C1-02)
Setting 1: Coast to stop
Setting 2: Fast Stop (uses the Fast Stop time set to C1-09)
Setting 3: Alarm only
Setting 4: No alarm display
Note:
Due to potential damage to motor and machinery, the “Alarm only” and “No alarm display” setting should be used only under
special circumstances.
n
F1-03, F1-08, F1-09: Overspeed (oS) Operation Selection, Detection Level, Delay Time
An overspeed error (oS) is triggered when the speed feedback exceeds the value set in F1-08 for longer than the time set
in F1-09. The stopping method when an overspeed fault occurs can be selected in parameter F1-03.
Port
Parameters
CN5-C and CN5-B
(common)
F1-02 to F1-04, F1-08 to F1-11, F1-14
CN5-C only
F1-01, F1-05, F1-06, F1-20
CN5-B only
F1-31, F1-32, F1-35, F1-36
No.
Parameter Name
Option Port
Setting Range
Default
F1-01
<1> For details on the default settings, refer to
Control Mode Dependent Parameter Default Values on page 84
PG 1 Pulses Per Revolution
CN5-C
0 to 60000 ppr
Determined by A1-02
F1-31
PG 2 Pulses Per Revolution
CN5-B
0 to 60000 ppr
Determined by A1-02
No.
Parameter Name
Option Port
Setting Range
Default
F1-02
Operation Selection at PG Open Circuit (PGo)
CN5-B, CN5-C
0 to 4
1
F1-14
PG Open-Circuit Detection Time
CN5-B, CN5-C
0.0 to 10.0 s
2.0 s
No.
Parameter Name
Option Port
Setting Range
Default
F1-03
<1> For details on the default settings, refer to
Control Mode Dependent Parameter Default Values on page 84
Operation Selection at Overspeed (oS)
CN5-B, CN5-C
0 to 3
1
F1-08
Overspeed Detection Level
CN5-B, CN5-C
0 to 120%
115%
F1-09
Overspeed Detection Delay Time
CN5-B, CN5-C
0.0 to 2.0 s
MV1000ParameterGuide_E_conditional.book 163 ページ 2013年10月11日 金曜日 午後8時18分