9.3 Model Specifications (400 V Class)
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
431
9.3
Model Specifications (400 V Class)
Table 9.3 Rating (400 V Class)
Model
4002
4003
4005
4006
4007
4009
4015
4018
4024
4031
4039
Maximum Applicable Motor Output
(kW)
0.55
1.1
1.5
2.2
3
4.0
5.5
7.5
11
15
18.5
Input
Rated
Input
Current
(A)
AC
1.9
3.5
4.7
6.7
8.9
11.7
15.8
21.2
30.6
41.3
50.5
DC
2.3
4.3
5.8
8.2
11
15
20
26
38
51
62
Output
Rated Output Capacity
(kVA)
1.2
2.2
3.2
3.6
4.7
6.1
10
12
16
20
26
Rated Output Current
(A)
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18
24
31
39
Overload Tolerance
150% of the rated output current for 60 s
Note:
Derating can be necessary for applications that start and stop frequently.
Carrier Frequency
8 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Maximum Output
Voltage
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output
Frequency
•
AOLV (Advanced Open Loop Vector): 120 Hz
•
CL-V/f (Closed Loop V/f Control), CLV (Closed Loop Vector): 400 Hz
•
V/f (V/f Control), OLV (Open Loop Vector): 590 Hz
Measures
for
Harmonics
DC reactor
External options
Braking
Device
Braking Transistor
Standard internal characteristics
EMC
Filter
EMC Filter
IEC61800-3, C3
Factory option
•
Models 4xxxB: There is a category C3 EMC filter in the drive.
Power
Supply
Rated Voltage/Rated
Frequency
•
Three-phase AC power supply 380 V to 480 V at 50/60 Hz
•
DC power supply 513 V to 679 V
Permitted Voltage
Fluctuation
-15% to +10%
Permitted Frequency
Fluctuation
±5%
Input Power
(kVA)
1.5
2.8
3.7
5.3
7.1
9.3
13
17
24
33
40
*1
The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2
Assumes the value at the rated output current. The input current rating changes when the power supply transformer, input reactor,
wiring connections, or power supply impedance change.
*3
The rated output capacity is calculated with a rated output voltage of 380 V.
*4
The power supply capacity is calculated with the voltage between lines at 480 V.
Table 9.4 Rating (400 V Class)
Model
4045
4060
4075
4091
4112
4150
4180
4216
4260
4304
4371
Maximum Applicable Motor Output
(kW)
22
30
37
45
55
75
90
110
132
160
200
Input
Rated
Input
Current
(A)
AC
43.1
58.3
71.5
86.5
105
142
170
207
248
300
373
DC
53
72
88
106
129
174
209
254
304
367
457
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...