3.10 Crane Application Setup Procedure
222
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
*3
Detection as a fault or minor fault is only applicable to the motor selected by the motor switch function. A fault or minor fault is
output when conditions are satisfied for the selected motor.
*4
When replacing a drive, set
S2-09 to S2-11
with the startup count information in the old drive.
Figure 3.11 Example Maintenance Monitor Operation (Run Command count: S2-08 = 0)
S2-09 - Motor1 Number of Driving start
S2-13 - Motor1 Number of Driving Limit
U4-54 - Num of Driv 1 (High)
U4-53 - Num of Driv 1 (Low)
■
Related Parameters
Table 3.26 Maintenance Monitor Parameters
No.
Name
Adjustment Method
S2-08
Number of Driving count selec
Sets the type of startup count for motors 1 to 3.
0: Run Command count
1: Brake Release Command count
S2-09
Motor1 Number of Driving start
Sets the motor 1 startup count in increments of 10,000 repetitions. Starts counting from the set
value value.
S2-10
Motor2 Number of Driving start
Sets the motor 2 startup count in increments of 10,000 repetitions. Starts counting from the set
value value.
S2-11
Motor3 Number of Driving start
Sets the motor 3 startup count in increments of 10,000 repetitions. Starts counting from the set
value value.
S2-12
MentenanceTimer Output Selection
Sets the method of alarm output.
0: Disable
1: Alarm
2: Fault
Motor1 Number of Driving Limit
Sets the startup count 1 fault/minor fault output level in increments of 10,000 repetitions.
CnT1
is detected when
S2-13 = U4-54
.
Motor2 Number of Driving Limit
Sets the startup count 2 fault/minor fault output level in increments of 10,000 repetitions.
CnT2
is detected when
S2-14 = U4-56
.
Motor3 Number of Driving Limit
Sets the startup count 3 fault/minor fault output level in increments of 10,000 repetitions.
CnT3
is detected when
S2-15 = U4-58
.
*1
These parameters are not initialized by
A1-03 [Initialize Parameters]
.
*2
The setting value of these parameters changes in accordance with the applicable monitor. For example, when the Run command
count reaches 10,000 after
S2-09 is set to 1
, the value of
U4-54
changes from 1 to 2.
S2-09 also changes to 2
at this same timing.
*3
When, S2-13 through S2-15 = 0, the startup count warning output setting is disabled.
■
Digital Outputs
H2-xx
Setting
Name
Description
52
Warning Signal
The terminal turns on when the number of starts reaches the detection level.
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...