0 : mV/(rev/min)
1 : mV/(rad/s)
Note:
•
When
T2-13 = 0
, the drive will use
E5-24 [PM Back-EMF L-L Vrms (mV/rpm)]
and will automatically set
E5-09 [PM Back-EMF
Vpeak (mV/(rad/s))] = 0.0
.
•
When
T2-13 = 1
, the drive will use
E5-09
and will automatically set
E5-24 = 0.0
.
■
T2-14: Back-EMF Voltage Constant (Ke)
No.
(Hex.)
Name
Description
Default
(Range)
T2-14
(0737)
Back-EMF Voltage
Constant (Ke)
Sets the motor induced voltage constant (Ke).
Determined by T2-13
(0.0 - 2000.0)
■
T2-15: Pull-In Current Level
No.
(Hex.)
Name
Description
Default
(Range)
T2-15
(0756)
Pull-In Current Level
Sets the level of the pull-in current as a percentage of
E5-03 [PM Motor Rated Current (FLA)]
.
Usually it is not necessary to change this setting.
30%
(0 - 120%)
If the load inertia is high, increase the setting value.
◆
T3: ASR and Inertia Tuning
■
T3-00: Control Loop Tuning Selection
No.
(Hex.)
Name
Description
Default
(Range)
T3-00
(1198)
Control Loop Tuning
Selection
Sets the type of Control Auto-Tuning.
2
(2, 3)
2 : Deceleration Rate Tuning
3 : KEB Tuning
◆
T4: EZ Tuning
Use
T4 parameters
to input the data necessary for motor parameter Auto-Tuning when
A1-02 = 8 [Control
Method Selection = EZ Vector Control]
. These two modes are available:
T4-01 Setting
Operational overview
Items input for tuning
Items tuned
0
Follow the instructions in the setup wizard on the keypad to
manually enter the necessary motor parameters.
•
T4-02 [Motor Type Selection]
•
T4-03 [Motor Max Revolutions]
•
T4-04 [Motor Rated Revolutions]
•
T4-05 [Motor Rated Frequency]
•
T4-06 [Motor Rated Voltage]
•
T4-07 [Motor Rated Current]
•
T4-08 [Motor Rated Capacity]
•
T4-09 [Number of Poles]
•
E9-01 [Motor Type Selection]
•
E9-02 [Maximum Speed]
•
E9-03 [Rated Speed]
•
E9-04 [Base Frequency]
•
E9-05 [Base Voltage]
•
E9-06 [Motor Rated Current (FLA)]
•
E9-07 [Motor Rated Power]
•
E9-08 [Motor Pole Count]
•
E9-09 [Motor Rated Slip]
•
E9-10 [Motor Line-to-Line Resistance]
1
Do only line-to-line resistance tuning.
Motor Rated Current
E9-10 [Motor Line-to-Line Resistance]
*1
When you use a PM motor or a synchronous reluctance motor, it is not necessary to enter the rated frequency. The drive will use the
rated rotation speed and number of motor poles to automatically calculate the rated frequency.
■
T4-01: EZ Tuning Mode Selection
No.
(Hex.)
Name
Description
Default
(Range)
T4-01
(3130)
EZ Tuning Mode Selection
Sets the type of Auto-Tuning for EZOLV control.
0
(0, 1)
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...