76: Down 2 Command
Setting Value
Function
Description
76
Down 2 Command
Sets the function to decrease the frequency reference bias value to decelerate the motor when the terminal is activated. Set this
function and
H1-xx = 75 [Up 2 Command]
at the same time.
When you activate the terminal set for Up2 Command, the bias will increase. When you activate the terminal set
for Down 2 Command, the bias will decrease. When you activate or deactivate the two commands, the drive will
hold the frequency reference.
Note:
•
When using this function, set the optimal bias limit value with
d4-08 and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit]
.
•
Refer to
“
d4: Frequency Ref Up/Down & Hold
”
for more information.
■
77: ASR Gain (C5-03) Select
Setting Value
Function
Description
77
ASR Gain (C5-03) Select
Sets the function to switch the ASR proportional gain set in
C5-01 [ASR Proportional Gain 1]
and
C5-03 [ASR Proportional
Gain 2]
.
ON : C5-03
Switches the proportional gain to
C5-03 [ASR Proportional Gain 2]
.
OFF : C5-01
Switches the proportional gain to
C5-01 [ASR Proportional Gain 1]
.
Note:
Refer to
“
C5: Automatic Speed Regulator (ASR)
”
for more information.
■
7A: KEB Ride-Thru 2 Activate (N.C.)
Setting Value
Function
Description
7A
KEB Ride-Thru 2 Activate
(N.C.)
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
When KEB Ride-Thru 2 is input, the drive will use Single Drive KEB Ride-Thru 2 for KEB operation. The
L2-29
[KEB Method Selection]
setting will not have an effect.
Note:
•
If you set
KEB Ride-Thru 1 [H1-xx = 65, 66]
and
KEB Ride-Thru 2 [H1-xx = 7A, 7B]
at the same time, the drive will detect
oPE03
[Multi-Function Input Setting Err]
.
•
Refer to
“
KEB Ride-Thru function
”
for more information.
■
7B: KEB Ride-Thru 2 Activate (N.O.)
Setting Value
Function
Description
7B
KEB Ride-Thru 2 Activate
(N.O.)
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
When KEB Ride-Thru 2 is input, the drive will use Single Drive KEB Ride-Thru 2 for KEB operation. The
L2-29
[KEB Method Selection]
setting will not have an effect.
Note:
•
If you set
KEB Ride-Thru 1 [H1-xx = 65, 66]
and
KEB Ride-Thru 2 [H1-xx = 7A, 7B]
at the same time, the drive will detect
oPE03
[Multi-Function Input Setting Err]
.
•
Refer to
“
KEB Ride-Thru function
”
for more information.
■
7C: Short Circuit Braking (N.O.)
Setting Value
Function
Description
7C
Short Circuit Braking
(N.O.)
Sets operation of Short Circuit Braking (N.O.).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...