![YASKAWA CIPR-GA50C series Technical Manual Download Page 322](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765322.webp)
322
YASKAWA
SIEPC71061753A GA500 Technical Manual
10.7
Drive Derating
You must derate the drive capacity to operate the drive above the rated temperature, altitude, and default carrier
frequency.
◆
Carrier Frequency Settings and Rated Current Values
The tables in this section show how the drive rated output current changes when the
C6-02 [Carrier Frequency
Selection]
value changes. The output current value changes linearly as the carrier frequency changes. You can use
the values from the tables to calculate a frequency that is not shown.
■
Three-Phase 200 V Class
Table 10.11 Carrier Frequency and Rated Current Derating (Three-Phase 200 V)
Model
Rated Current (A)
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
2 kHz
5 kHz
8 kHz
10 kHz
12.5 kHz
15 kHz
2 kHz
5 kHz
8 kHz
10 kHz
12.5 kHz
15 kHz
2001
0.8
0.8
0.8
0.8
0.7
0.6
1.2
1.1
1.0
0.9
0.8
0.6
2002
1.6
1.6
1.6
1.6
1.4
1.3
1.9
1.9
1.7
1.6
1.4
1.3
2004
3.0
3.0
3.0
3.0
2.7
2.4
3.5
3.5
3.2
3.0
2.7
2.4
2006
5.0
5.0
5.0
5.0
4.5
4
6.0
6.0
5.4
5.0
4.5
4
2010
8.0
8.0
8.0
7.5
7.0
6.4
9.6
9.1
8.3
7.7
7.1
6.4
2012
11.0
11.0
11.0
10.4
9.6
8.8
12.2
11.9
11.0
10.4
9.6
8.8
2021
17.6
17.6
17.6
16.6
15.3
14.1
21.0
19.8
18.1
17.0
15.5
14.1
2030
25.0
25.0
25.0
23.6
21.8
20
30.0
28.3
25.8
24.2
22.1
20
2042
33.0
33.0
33.0
31.1
28.8
26
42.0
39.4
35.5
32.9
29.7
26
2056
47.0
47.0
47.0
44.3
41.0
38
56.0
52.9
48.3
45.3
41.4
38
2070
60.0
60.0
60.0
56.6
52.3
48
70.0
66.3
60.8
57.2
52.6
48
2082
75.0
75.0
75.0
70.7
65.4
60
82.0
81.4
75.0
70.7
65.4
60
Table 10.12 AOLV/PM Carrier Frequency and Rated Current Derating (Three-Phase 200 V)
Model
Rated Current (A)
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
2 kHz
4 kHz
6 kHz
8 kHz
10 kHz
12 kHz
2 kHz
4 kHz
6 kHz
8 kHz
10 kHz
12 kHz
2001
0.8
0.8
0.8
0.7
0.6
0.5
1.2
1.1
0.9
0.8
0.6
0.5
2002
1.6
1.6
1.6
1.5
1.3
1.1
1.9
1.9
1.7
1.5
1.3
1.1
2004
3.0
3.0
3.0
2.8
2.4
2.0
3.5
3.5
3.1
2.8
2.4
2.0
2006
5.0
5.0
5.0
4.6
4.0
3.4
6.0
5.8
5.2
4.6
4.0
3.4
2010
8.0
8.0
7.8
7.1
6.4
5.7
9.6
8.8
8.0
7.2
6.4
5.6
2012
11.0
11.0
10.7
9.7
8.8
7.9
12.2
11.6
10.7
9.7
8.8
7.9
2021
17.6
17.6
17.1
15.6
14.1
12.6
21.0
19.3
17.5
15.8
14.1
12.4
2030
25.0
25.0
24.3
22.1
20.0
17.9
30.0
27.5
25.0
22.5
20.0
17.5
2042
33.0
33.0
32.1
29.2
26.4
23.6
42.0
38.1
34.2
30.3
26.4
22.5
2056
47.0
47.0
45.7
41.6
37.6
33.6
56.0
51.4
46.8
42.2
37.6
33.0
2070
60.0
60.0
58.3
53.1
48.0
42.9
70.0
64.5
59.0
53.5
48.0
42.5
2082
75.0
75.0
72.9
66.4
60.0
53.6
82.0
79.3
72.9
66.4
60.0
53.6
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...