![YASKAWA CIPR-GA50C series Technical Manual Download Page 313](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765313.webp)
YASKAWA
SIEPC71061753A GA500 Technical Manual
313
10.2
Drive Duty Modes
The drive has two duty modes from which to select for the application: Heavy Duty (HD) and Normal Duty (ND).
Refer to
for information about the differences between HD and ND ratings.
Table 10.1 Drive Duty Modes
Duty Rating
C6-01
Setting
Application
Default Carrier Frequency
Overload Tolerance (oL2
[Drive Overload])
Heavy Duty Rating
(HD)
0
•
Extruder
•
Conveyor
•
Cranes and hoists
•
Constant torque or high overload capacity
Determined by o2-04, A1-02
150% of the rated output current for
60 seconds The permitted
frequency of overload is once every
10 minutes.
Normal Duty Rating
(ND)
1
•
Fan
•
Pump
•
Blower
•
Variable speed control
Determined by o2-04, A1-02
110% of the rated output current for
60 seconds The permitted
frequency of overload is once every
10 minutes.
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...