-138
Time Chart
A time chart for the zero servo function is given in
Fig 6.74 Time Chart for Zero Servo
.
Fig 6.74 Time Chart for Zero Servo
Application Precautions
•
Be sure to leave the run command input ON. If the run command is turned OFF, the output will be inter-
rupted and the zero-servo function will become ineffective.
•
The holding force of the zero-servo is adjusted in b9-01. The holding force will increase if the value of the
setting is increased, but oscillation and hunting will occur if the setting is too large. Adjust b9-01 after
adjusting the speed control gain.
•
The zero-servo detection width is set as the allowable position offset from the zero-servo start position. Set
4 times the number of pulses from the PG.
•
The Zero Servo End signal will go OFF when the zero servo command is turned OFF.
IMPORTANT
Do not lock the servo for extended periods of time at 100% when using the zero servo function. Drive errors
may result. Extended periods of servo lock can be achieved by ensuring that the current during the servolock
is 50% or less or by increasing the Drive capacity.
Run command
ON
OFF
Zero servo command
Frequency (speed) reference
Excitation level
b2-01
Motor speed
Zero Servo End signal
Zero-servo status
ON
OFF